Respiratory inductive plethysmography in the evaluation of lower airway obstruction during methacholine challenge in infants.

F Rusconi1, L Gagliardi, H Aston, M Silverman.   

Abstract

Respiratory inductive plethysmography (RIP) is a simple technique for an objective, noninvasive assessment of thoracoabdominal asynchrony, which in turn is an indirect measure of airway obstruction. We evaluated different indices of asynchrony obtained by RIP before and after methacholine-induced airway obstruction. Bronchial obstruction was elicited by progressive doubling concentrations of methacholine until a > 15% fall in the transcutaneous oxygen tension (PtcO2) had developed. Maximal expiratory flow rates at functional residual capacity (FRC) (VmaxFRC) was obtained by the squeeze technique before and after the challenge. Fifteen infants with a history of wheezing were studied after sedation. Thoracoabdominal movements were recorded with RIP bands placed around either the upper or the lower ribcage (RC) and around the abdomen (AB). An inspiratory asynchrony index (IAI) and an expiratory asynchrony index (EAI) were calculated as determined by the lag of RC relative to AB at start of inspiration and of expiration, respectively. The total time in asynchrony (TTA: the percentage of time in which the RC and the AB signals were in opposite direction) and phi (an angle derived from a Lissajous loop) were also calculated. All subjects responded to the challenge. The median fall in PtcO2 following methacholine challenge was 23.6% and in VmaxFRC was 43%. A large scatter of baseline values was found for all indices with the exception of TTA. There was no correlation between TTA and age, length, or VmaxFRC. The IAI and EAI with the RC band in the upper position were the most sensitive indices, both within subjects (65% of the subjects had a significant change in IAI and 80% in EAI) and for the group as a whole (median values increased for IAI, P = 0.007, and for EAI, P = 0.017). TTA and phi were less sensitive, and a great discrepancy was observed between the two measurements. Poor results were obtained with the RC band in the lower position. No correlations were found between the changes in IAI and EAI, with the RC band around the lower chest and VmaxFRC. We conclude that IAI and EAI, measured with the RC band in the upper position and another band around the abdomen, can detect changes in thoracoabdominal asynchrony in most infants. The usefulness of assessing IAI and EAI in infants with acute lower airway obstruction needs to be determined.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8649920     DOI: 10.1002/ppul.1950200610

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  3 in total

1.  Work of breathing indices in infants with respiratory insufficiency receiving high-flow nasal cannula and nasal continuous positive airway pressure.

Authors:  B E de Jongh; R Locke; A Mackley; J Emberger; D Bostick; J Stefano; E Rodriguez; T H Shaffer
Journal:  J Perinatol       Date:  2013-09-26       Impact factor: 2.521

2.  Nocturnal thoracoabdominal asynchrony in house dust mite-sensitive nonhuman primates.

Authors:  Xiaojia Wang; Shaun Reece; Stephen Olmstead; Robert L Wardle; Michael R Van Scott
Journal:  J Asthma Allergy       Date:  2010-07-28

3.  Acute effects of transcutaneous electrical diaphragmatic stimulation on respiratory pattern in COPD patients: cross-sectional and comparative clinical trial.

Authors:  Karina M Cancelliero-Gaiad; Daniela Ike; Camila B F Pantoni; Renata G Mendes; Audrey Borghi-Silva; Dirceu Costa
Journal:  Braz J Phys Ther       Date:  2013-11-14       Impact factor: 3.377

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.