Literature DB >> 8648453

Premature infant responses to noise reduction by earmuffs: effects on behavioral and physiologic measures.

L K Zahr1, J de Traversay.   

Abstract

The continuous high-intensity noise in the neonatal intensive care unit (NICU) is both stressful and harmful for the premature infant. Although some researchers have found evidence that loud noise can cause hearing loss and alter physiologic and behavioral responses, no study to date has investigated the benefits of noise reduction by the use of earmuffs. In this study earmuffs were placed over the premature infants' ears to reduce noise intensity in the NICU while physiologic and behavioral responses were measured. Two sites were used to collect data: in the first setting, 17 low birth weight infants were randomly assigned to an experimental and a control group, whereas 13 infants from a second hospital acted as their own controls and were tested with and without earmuffs. Earmuffs that reduced the intensity of noise by 7 to 12 dB were worn by infants in the experimental group only during the observation periods. Infants in the control group were exposed to the usual noise in the NICU. The infant's physiologic and behavioral responses were observed for four 2-hour intervals, morning and evening, on two consecutive days. Most of the significant results were from the site at which infants acted as their own controls. When infants wore the earmuffs, they had significantly higher mean oxygen saturation levels and less fluctuation in oxygen saturation. Furthermore, these infants had less frequent behavioral state changes, spent more time in the quiet sleep state, and had longer bouts in the sleep state. It is imperative that NICUs develop aggressive antinoise policies to substantially and consistently reduce noise.

Entities:  

Mesh:

Year:  1995        PMID: 8648453

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  15 in total

1.  Noise levels within the ear and post-nasal space in neonates in intensive care.

Authors:  S S Surenthiran; K Wilbraham; J May; T Chant; A J B Emmerson; V E Newton
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-07       Impact factor: 5.747

Review 2.  Impact of hospital-based environmental exposures on neurodevelopmental outcomes of preterm infants.

Authors:  Janelle Santos; Sarah E Pearce; Annemarie Stroustrup
Journal:  Curr Opin Pediatr       Date:  2015-04       Impact factor: 2.856

3.  Sedation, sleep promotion, and delirium screening practices in the care of mechanically ventilated children: a wake-up call for the pediatric critical care community*.

Authors:  Sapna R Kudchadkar; Myron Yaster; Naresh M Punjabi
Journal:  Crit Care Med       Date:  2014-07       Impact factor: 7.598

Review 4.  Pediatric neuroimaging in early childhood and infancy: challenges and practical guidelines.

Authors:  Nora Raschle; Jennifer Zuk; Silvia Ortiz-Mantilla; Danielle D Sliva; Angela Franceschi; P Ellen Grant; April A Benasich; Nadine Gaab
Journal:  Ann N Y Acad Sci       Date:  2012-04       Impact factor: 5.691

5.  Laboratory personnel gender and cold pressor apparatus affect subjective pain reports.

Authors:  Jacob M Vigil; Lauren N Rowell; Joe Alcock; Randy Maestes
Journal:  Pain Res Manag       Date:  2013-12-23       Impact factor: 3.037

6.  Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform.

Authors:  Anton Aboukhalil; Larry Nielsen; Mohammed Saeed; Roger G Mark; Gari D Clifford
Journal:  J Biomed Inform       Date:  2008-03-21       Impact factor: 6.317

7.  Excessive exposure of sick neonates to sound during transport.

Authors:  L Buckland; N Austin; A Jackson; T Inder
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-11       Impact factor: 5.747

8.  Exposure to virtual social stimuli modulates subjective pain reports.

Authors:  Jacob M Vigil; Daniel Torres; Alexander Wolff; Katy Hughes
Journal:  Pain Res Manag       Date:  2014-06-09       Impact factor: 3.037

Review 9.  Developmental care for promoting development and preventing morbidity in preterm infants.

Authors:  A Symington; J Pinelli
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

10.  A pilot study to assess the safety, efficacy and ease of use of a novel hearing protection device for hospitalized neonates.

Authors:  Michael J Balsan; Jeanne Burns; Fred Kimock; Emily Hirsch; Andrew Unger; Richard Telesco; Elisabeth Bloch-Salisbury
Journal:  Early Hum Dev       Date:  2021-03-26       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.