Literature DB >> 8648311

Femoral articular shape and geometry. A three-dimensional computerized analysis of the knee.

D Siu1, J Rudan, H W Wevers, P Griffiths.   

Abstract

An average, three-dimensional anatomic shape and geometry of the distal femur were generated from x-ray computed tomography data of five fresh asymptomatic cadaver knees using AutoCAD (AutoDesk, Sausalito, CA), a computer-aided design and drafting software. Each femur model was graphically repositioned to a standardized orientation using a series of alignment templates and scaled to a nominal size of 85 mm in mediolateral and 73 mm in anteroposterior dimensions. An average generic shape of the distal femur was synthesized by combining these pseudosolid models and reslicing the composite structure at different elevations using clipping and smoothing techniques in interactive computer graphics. The resulting distal femoral geometry was imported into a computer-aided manufacturing system, and anatomic prototypes of the distal femur were produced. Quantitative geometric analyses of the generic femur in the coronal and transverse planes revealed definite condylar camber (3 degrees-6 degrees) and toe-in (8 degrees-10 degrees) with an oblique patellofemoral groove (15 degrees) with respect to the mechanical axis of the femur. In the sagittal plane, each condyle could be approximated by three concatenated circular arcs (anterior, distal, and posterior) with slope continuity and a single arc for the patellofemoral groove. The results of this study may have important implications in future femoral prosthesis design and clinical applications.

Entities:  

Mesh:

Year:  1996        PMID: 8648311     DOI: 10.1016/s0883-5403(05)80012-9

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  The cartilaginous and osseous geometry of the femoral trochlear groove.

Authors:  Yi-Fen Shih; Anthony M J Bull; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-10-03       Impact factor: 4.342

2.  Gender differences in the knees of Chinese population.

Authors:  Bing Yue; Kartik M Varadarajan; Songtao Ai; Tingting Tang; Harry E Rubash; Guoan Li
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-21       Impact factor: 4.342

3.  [The medial patellofemoral ligament: function, injury, and treatment].

Authors:  P J Erasmus
Journal:  Orthopade       Date:  2008-09       Impact factor: 1.087

4.  Use of anthropometric data from the medial tibial and femoral condyles to design unicondylar knee prostheses in the Chinese population.

Authors:  Fu Bo Cheng; Xiao Feng Ji; Wen Xu Zheng; Ying Lai; Kai Liang Cheng; Jia Chun Feng; You Qiong Li
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

5.  The 3D analysis of the sagittal curvature of the femoral trochlea in the Chinese population.

Authors:  Jun Wang; Bing Yue; You Wang; Mengning Yan; Yiming Zeng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-24       Impact factor: 4.342

6.  Does total knee arthroplasty modify flexion axis of the knee?

Authors:  F Iacono; D Bruni; S Bignozzi; F Colle; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-15       Impact factor: 4.342

7.  Difference in coronal curvature of the medial and lateral femoral condyle morphology by gender in implant design for total knee arthroplasty.

Authors:  Yong-Gon Koh; Ji-Hoon Nam; Hyun-Seok Chung; Kyoung-Tak Kang
Journal:  Surg Radiol Anat       Date:  2019-11-04       Impact factor: 1.246

8.  Osteochondral allograft transplant to the medial femoral condyle using a medial or lateral femoral condyle allograft: is there a difference in graft sources?

Authors:  Timothy S Mologne; Esther Cory; Bradley C Hansen; Angela N Naso; Neil Chang; Michael M Murphy; Matthew T Provencher; William D Bugbee; Robert L Sah
Journal:  Am J Sports Med       Date:  2014-07-17       Impact factor: 6.202

9.  Design and Control of a New Biomimetic Transfemoral Knee Prosthesis Using an Echo-Control Scheme.

Authors:  Mario G Bernal-Torres; Hugo I Medellín-Castillo; Juan C Arellano-González
Journal:  J Healthc Eng       Date:  2018-04-30       Impact factor: 2.682

Review 10.  Recent advances in computational mechanics of the human knee joint.

Authors:  M Kazemi; Y Dabiri; L P Li
Journal:  Comput Math Methods Med       Date:  2013-02-19       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.