Literature DB >> 8644637

Comparison of the diagnostic potential of four echocardiographic stress tests shortly after acute myocardial infarction: submaximal exercise, transesophageal atrial pacing, dipyridamole, and dobutamine-atropine.

K Schröder1, H Völler, H Dingerkus, H Münzberg, R Dissmann, T Linderer, H P Schultheiss.   

Abstract

This study assessed and compared the diagnostic potential of submaximal exercise, transesophageal atrial pacing, dipyridamole, and dobutamine-atropine stress echocardiography tests shortly after acute myocardial infarction. In 121 study patients, 325 digital echocardiographic stress tests were attempted 10 to 11 days after acute myocardial infarction: 83 submaximal exercise tests, 121 high-dose dipyridamole echocardiography tests (DET), 69 transesophageal atrial pacing tests (< 150 beats/min), and 52 dobutamine tests, starting at 10 microgram/kg per minute, increasing stepwise to 40 microgram kg/min, and coadministering atropine in 12 patients (dobutamine-atropine stress echocardiography [DASE]). Results were correlated to a coronary artery diameter stenosis > or = 50% as determined by quantitative angiography. Feasibility to perform submaximal exercise echocardiography, atrial pacing echocardiography, DET, and DASE was 89%, 52%, 98%, and 88%, respectively. Atrial pacing was not tolerated by 18 patients and refused by 6 (9%). Severe but not life-threatening side effects were hypotension in DET (2%) and tachyarrhythmias in DASE (6%). Test positivity in multivessel disease with submaximal exercise, DET, and DASE was 55%, 93%, and 90%, respectively, and in 1-vessel disease 47%, 65%, 71%, and for atrial pacing, 82%, respectively. We conclude that submaximal exercise has limited sensitivity and atrial pacing limited feasibility. The pharmacologic stressors provide a useful, safe diagnostic approach: DET with slightly lower sensitivity in 1-vessel disease and DASE with insignificantly less feasibility.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8644637     DOI: 10.1016/s0002-9149(96)00027-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Factors influencing the diagnostic accuracy of dobutamine stress echocardiography.

Authors:  K Schröder; R Agrawal; H Völler; B Kürsten; R Dissmann; H P Schultheiss
Journal:  Int J Card Imaging       Date:  1997-12

2.  Stress echocardiography for the diagnosis of coronary artery disease: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01

3.  Pharmacological and simulated exercise cardiac stress tests produce different ischemic signatures in high-resolution experimental mapping studies.

Authors:  Brian Zenger; Wilson W Good; Jake A Bergquist; Lindsay C Rupp; Maura Perez; Gregory J Stoddard; Vikas Sharma; Rob S MacLeod
Journal:  J Electrocardiol       Date:  2021-07-24       Impact factor: 1.380

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.