Literature DB >> 8642820

Randomized comparison of ultrasonic aspiration versus conventional electrocautery for dissection of the human internal thoracic artery.

K L Blake1, P A Watt, J M Smith, A C De Souza, T J Spyt, H Thurston.   

Abstract

The most common technique currently employed to harvest the internal thoracic artery for coronary artery bypass grafting is conventional electrocautery. This study compared an alternative method, electrocautery with an ultrasonic aspirator, for harvesting the internal thoracic artery. Patients were randomly assigned to one of six experimental groups (conventional electrocautery, ultrasonic aspirator at settings of 60%, 80%, and 100% power output, and ultrasonic aspirator in 100% CAVI-Pulse modes 1 and 3). Ring segments of internal thoracic artery were studied in an organ bath. Contraction responses were elicited with 123 mmol/L potassium physiologic salt solution, KPSS, KPSS solution containing noradrenaline, and a cumulative noradrenaline dose-contraction curve. Relaxation studies were performed with the vasodilators acetylcholine, bradykinin, and sodium nitroprusside. Forty percent of the electrocauterized vessels were traumatized or damaged and failed to respond to contractile stimuli, whereas only 10% of the vessels in ultrasonic aspirator groups 60%, 80%, and 100% failed to respond. All vessels in the group harvested by ultrasonic aspirator in 100% CAVI-Pulse mode 1 responded, whereas 20% of the vessels in the group harvested by ultrasonic aspirator in 100% CAVI-Pulse mode 3 failed to respond. All settings of electrocautery with an ultrasonic aspirator produced a greater contractile response to KPSS and noradrenaline. Acetylcholine and sodium nitroprusside produced similar relaxations in all groups, but the bradykinin responses were significantly improved in all groups undergoing 100% electrocautery with an ultrasonic aspirator. These results suggest that 100% electrocautery with an ultrasonic aspirator, particularly in 100% CAVI-Pulse mode 1, resulted in less damage and trauma than conventional electrocautery during harvesting of the internal thoracic artery.

Entities:  

Mesh:

Year:  1996        PMID: 8642820     DOI: 10.1016/s0022-5223(96)70221-0

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  3 in total

1.  Ultrasonic coagulator for video-assisted internal mammary artery harvest.

Authors:  T Ohtsuka; S Takamoto; M Endoh; Y Kotsuka; T Oka
Journal:  Surg Endosc       Date:  2000-01       Impact factor: 4.584

2.  Endoscopic harvesting of the left internal mammary artery.

Authors:  Tomasz Hrapkowicz; Gianluigi Bisleri
Journal:  Ann Cardiothorac Surg       Date:  2013-07

3.  Effect of electrocautery on endothelial integrity of the internal thoracic artery: ultrastructural analysis with transmission electron microscopy.

Authors:  Burak Onan; Mehmet Yeniterzi; Ismihan Selen Onan; Burak Ersoy; Suheyla Gonca; Elif Gelenli; Seyhun Solakoglu; Ihsan Bakir
Journal:  Tex Heart Inst J       Date:  2014-10-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.