The present state of trend detection and prediction in patient monitoring.

J Endresen, D W Hill.   

Abstract

An investigation has been carried out into the suitability of the following techniques for trend detection and forecasting in patient monitoring: Cusum; Trigg's Tracking Signal; The Patient Condition Factor; The Patient Alarm Warning System; Box-Jenkins models and the Harrison-Stevens Bayesian approach. The latter holds considerable promise since it is flexible and can be implemented on a microprocessor. Consideration has also been given to the need for a better knowledge of the statistical properties of the variables to be monitored and the problems of combining trends detected in severable variables.

Entities:  

Mesh:

Year:  1977        PMID: 864087     DOI: 10.1007/bf01683184

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  12 in total

1.  The analysis of radioisotope cardiac output dilution curves.

Authors:  D W Hill
Journal:  Med Biol Eng       Date:  1975-11

2.  A comparison of two methods for the computer analysis of arterial blood pressure waveforms.

Authors:  J Endresen; A Gamble; D W Hill
Journal:  Eur J Intensive Care Med       Date:  1975-11

3.  Short-term variability of pulse rate and blood pressure in cardiac surgery patients.

Authors:  D E Taylor; J S Whamond; D J Hitchings; M Hullinger; D Begg
Journal:  Cardiovasc Res       Date:  1975-11       Impact factor: 10.787

4.  Assessment of prognosis in acute myocardial infarction by computer analysis of cardio-respiratory variables.

Authors:  S Bevegård; P Blomqvist; J Hulting; G Matell; M E Nygårds; O Wigertz
Journal:  Acta Med Scand       Date:  1973 Jul-Aug

5.  Computed trend analysis in automated patient monitoring systems.

Authors:  C E Hope; C D Lewis; I R Perry; A Gamble
Journal:  Br J Anaesth       Date:  1973-05       Impact factor: 9.166

6.  An analogue preprocessor for the analysis of blood pressure.

Authors:  A M Sandman; D W Hill
Journal:  Med Biol Eng       Date:  1974-05

7.  Computer detection of distortion in arterial pressure signals.

Authors:  G Klee; E Ackerman; A Leonard
Journal:  IEEE Trans Biomed Eng       Date:  1974-01       Impact factor: 4.538

8.  Analogue preprocessor for the measurement by a digital computer of R-R intervals and R wave widths.

Authors:  A Sandman; D W Hill; A H Wilcock
Journal:  Med Biol Eng       Date:  1973-03

9.  Computer-assisted patient monitor systems.

Authors:  D E Taylor
Journal:  Biomed Eng       Date:  1971-12

10.  Reliability of human and machine measurements in patient monitoring.

Authors:  D E Taylor; J S Whamond
Journal:  Eur J Intensive Care Med       Date:  1975-05
View more
  1 in total

1.  The application of a modified proportional-derivative control algorithm to arterial pressure alarms in anesthesiology.

Authors:  J L Derrick; C L Thompson; T G Short
Journal:  J Clin Monit Comput       Date:  1998-01       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.