Literature DB >> 8640417

Ultrasound monitoring in cannulation of the internal jugular vein: anatomic and technical considerations.

B Docktor1, C B So, J C Saliken, R R Gray.   

Abstract

OBJECTIVE: To examine the effect of variations in anatomic features and operator experience on the success and complication rates of sonographically monitored cannulation of the internal jugular vein. PATIENTS AND METHODS: The authors prospectively collected data for ultrasound-monitored cannulation of the internal jugular vein in 150 patients. In all cases the radiologist recorded the side of puncture, the number of passes needed, the number of vein punctures (one or two), whether the walls were opposed during puncture and any complications. For the last 80 patients the following information was also recorded: the distance from the skin to the internal jugular vein, the diameter of the vein with the Valsalva manoeuvre and the location of the vein relative to the carotid artery. All but three of the cannulations were performed by one of three radiologists, all of whom had at least 5 years of experience.
RESULTS: Cannulation was successful in all of the patients, and the first pass was successful in 133 (88.7%). These results are better than those of blind placement techniques reported in the literature. The only complications were hematoma and carotid puncture, which both occurred in the same two patients (1.3%). There was no significant difference among the radiologists in the number of passes needed (one-way analysis of variance, p > 0.05). The number of passes was independent of anatomic factors, including depth from skin, vein diameter or relative location. However, significantly more passes were needed for left-side punctures than for right-side punctures (Student t-test, p < 0.05).
CONCLUSIONS: Real-time ultrasound monitoring is superior to blind techniques in cannulation of the internal jugular vein because of its ease, accuracy and safety. Sonographic real-time monitoring minimizes the impact of anatomic factors on success and complication rates. It is a safe and efficacious approach that should be preferred in the placement of central lines.

Entities:  

Mesh:

Year:  1996        PMID: 8640417

Source DB:  PubMed          Journal:  Can Assoc Radiol J        ISSN: 0846-5371            Impact factor:   2.248


  6 in total

Review 1.  Ultrasound-guided central vascular interventions, comments on the European Federation of Societies for Ultrasound in Medicine and Biology guidelines on interventional ultrasound.

Authors:  Christoph F Dietrich; Rudolf Horn; Susanne Morf; Liliana Chiorean; Yi Dong; Xin-Wu Cui; Nathan S S Atkinson; Christian Jenssen
Journal:  J Thorac Dis       Date:  2016-09       Impact factor: 2.895

2.  Impact of ultrasonography on central venous catheter insertion in intensive care.

Authors:  Gopal B Palepu; Juneja Deven; M Subrahmanyam; S Mohan
Journal:  Indian J Radiol Imaging       Date:  2009 Jul-Sep

3.  Ultrasound-guided versus landmark-guided femoral vein access in pediatric cardiac catheterization.

Authors:  S Iwashima; T Ishikawa; T Ohzeki
Journal:  Pediatr Cardiol       Date:  2007-09-13       Impact factor: 1.655

Review 4.  Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice.

Authors:  Bernd Saugel; Thomas W L Scheeren; Jean-Louis Teboul
Journal:  Crit Care       Date:  2017-08-28       Impact factor: 9.097

5.  Ultrasonographic assessment of altered anatomical relationship between internal jugular vein and common carotid artery with supraglottic airway in children: LMA vs i-gel™.

Authors:  Rakhi Khemka; Sonal Rastogi; Arunangshu Chakraborty; Subir Sinha
Journal:  Indian J Anaesth       Date:  2019-02

6.  Ultrasound guided internal jugular vein cannulation in infants: Comparative evaluation of novel modified short axis out of plane approach with conventional short axis out of plane approach.

Authors:  Amit Rastogi; Aarti Agarwal; Puneet Goyal; Vansh Priya; Sanjay Dhiraaj; Rudrashish Haldar
Journal:  Indian J Anaesth       Date:  2018-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.