Literature DB >> 8638601

The performance of bonded magnets used in the treatment of anterior open bite.

J H Noar1, N Shell, N P Hunt.   

Abstract

This investigation examined the magnetic flux and repulsive force of neodymium-iron-boron (Nd-Fe-B) magnets based on Nd2Fe14B with acrylic coatings in different orientations. The flux was measured with a Hall probe and the force measured by electronic scales with the magnets mounted on a laboratory jack. Results show that there were no magnetic losses after embedding the magnets in acrylic bite-blocks, although there were significant flux losses when the magnet blocks were directly heated. The alignment of the magnets over each other was of the utmost importance and significantly affected the repulsive force between the magnets. When the magnets were mounted in an articulator to simulate jaw movement, the force levels between the magnets was further reduced as a result of the effects of the rotation of the articulator. It is concluded that Nd-Fe-B type magnets embedded in acrylic can be used to give predictable repulsive forces in the mouth. The dramatic reduction in force levels when the magnets are not in optimal alignment, however, makes their effectiveness in aiding intrusion of teeth doubtful.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8638601     DOI: 10.1016/s0889-5406(96)70141-5

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  4 in total

Review 1.  Orthodontic treatment of anterior open bite: a review article--is surgery always necessary?

Authors:  Isabelle Reichert; Philipp Figel; Lindsay Winchester
Journal:  Oral Maxillofac Surg       Date:  2013-08-16

2.  Cephalometric comparison of adult anterior open bite treatment using clear aligners and fixed appliances.

Authors:  Bella Shen Garnett; Kimberly Mahood; Mai Nguyen; Aliaa Al-Khateeb; Siqi Liu; Robert Boyd; Heesoo Oh
Journal:  Angle Orthod       Date:  2018-10-03       Impact factor: 2.079

3.  Effects of a novel magnetic orthopedic appliance (MOA-III) on the dentofacial complex in mild to moderate skeletal class III children.

Authors:  Ning Zhao; Jing Feng; Zheng Hu; Rongjing Chen; Gang Shen
Journal:  Head Face Med       Date:  2015-10-14       Impact factor: 2.151

4.  Orthodontic traction of impacted canine using magnet: a case report.

Authors:  Larry Cf Li; Ricky Wk Wong; Nigel M King
Journal:  Cases J       Date:  2008-12-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.