Literature DB >> 8638599

Frictional resistances in stainless steel bracket-wire combinations with effects of vertical deflections.

R H Ogata1, R S Nanda, M G Duncanson, P K Sinha, G F Currier.   

Abstract

This research evaluated the effects of different bracket-wire combinations and second-order deflections on kinetic friction. Thirteen different brackets, six with 0.018 x 0.025 inch slots and seven with 0.022 x 0.028-inch slots were evaluated with six different sizes and shapes of stainless steel orthodontic wire, i.e., 0.016, 0.016 x 0.022, 0.017 x 0.025, 0.018, 0.018 x 0.025 and 0.019 x 0.026 inch for four second order deflections of 0.00, 0.25, 0.50, and 0.75 mm. The wires were ligated into the brackets with elastomeric modules. Bracket movement was implemented by means of an Instron universal testing instrument (RMO, Denver, Colo.), and frictional forces were measured by a tension load cell and recorded on an X-Y recorder (Hewlett-Packard, Anaheim, Calif.). Second-order deflection was created by a specially designed and machined testing apparatus that allowed two alternate pairs of the four total brackets to be offset in increments of 0.25 mm. The kinetic frictional force increased for every bracket-wire combination tested as the second-order deflection increased. Friction also increased with an increase in wire size, whereas rectangular wires produced greater friction than round wires. Bracket designs that limited the force of ligation on the wire generated less friction at low second-order deflections (0.00 and 0.25 mm).

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8638599     DOI: 10.1016/s0889-5406(96)70139-7

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  15 in total

1.  Lingual orthodontics (part 2): archwire fabrication.

Authors:  D Wiechmann
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  The influence of bracket design on frictional losses in the bracket/arch wire system.

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

3.  Ceramic brackets and low friction : A possible synergy in patients requiring multiple MRI scanning.

Authors:  Matteo Camporesi; Mariana Bulhoes Galvão; André Tortamano; Gladys Cristina Dominguez; Nicolò Defraia; Efisio Defraia; Lorenzo Franchi
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

4.  Friction behavior of ceramic injection-molded (CIM) brackets.

Authors:  Susanne Reimann; Christoph Bourauel; Anna Weber; Cornelius Dirk; Thomas Lietz
Journal:  J Orofac Orthop       Date:  2016-05-03       Impact factor: 1.938

5.  Influence of thermal or chemical degradation on the frictional force of an experimental coated NiTi wire.

Authors:  Ana Maria Bezerra Bandeira; Marcia Pereira Alves dos Santos; Gino Pulitini; Carlos Nelson Elias; Marysilva Ferreira da Costa
Journal:  Angle Orthod       Date:  2011-02-07       Impact factor: 2.079

6.  Friction properties according to vertical and horizontal tooth displacement and bracket type during initial leveling and alignment.

Authors:  Wook Heo; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2011-02-09       Impact factor: 2.079

7.  Canine retraction rate with self-ligating brackets vs conventional edgewise brackets.

Authors:  S Jack Burrow
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

8.  A comparison of resistance to sliding of self-ligating brackets under an increasing applied moment.

Authors:  Benjamin T Pliska; John P Beyer; Brent E Larson
Journal:  Angle Orthod       Date:  2011-05-13       Impact factor: 2.079

9.  Evaluation of the friction of self-ligating and conventional bracket systems.

Authors:  Simona Tecco; Donato Di Iorio; Riccardo Nucera; Beatrice Di Bisceglie; Giancarlo Cordasco; Felice Festa
Journal:  Eur J Dent       Date:  2011-07

10.  A comparative study of frictional resistance during simulated canine retraction on typodont model.

Authors:  Ram Sukh; Gulshan K Singh; Pradeep Tandon; Gyan P Singh; Alka Singh
Journal:  J Orthod Sci       Date:  2013-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.