Literature DB >> 863749

A microfluorescent PAS method for the quantitative demonstration of cytoplasmic 1,2-glycols.

D G Changaris, J Combs, W B Severs.   

Abstract

Fluorescent microspectrophotometry using dichroic mirror vertical epi-illumination of tissue sections stained with the PAS reaction (periodic acid and pararosaniline Schiff reagent) provides a measure of the relative concentration of 1:2 glycols within and between tissue sections. In PAS reacted sections of agarose gel, pararosaniline Schiff fluorescence increases linearly as the concentration of agarose increases (r=0.97, p less than 0.05). The concentration of glycogen within liver as measured by a phenol-based tissue assay is linearly correlated with pararosaniline Schiff fluorescence of formalin fixed liver sections (r-0.87, p less than 0.05). These relationships are unaffected by alcian blue or hematoxylin. Heretofore the amount of color reaction as measured by densitometry at the pararosaniline absorption peak was claimed to be an unreliable indicator of the amount of reactive glycol present in tissue. Our observations indicate that when the concentration of Schiff reagent exceeds an empiric limit relative to available polysaccharides, the Schiff reagent-tissue complex reflects light at the excitation wavelength instead of fluorescing the emission spectra. This can be circumvented by using dilute pararosaniline-Schiff reagent, shorteining the staining period, and lowering the temperature of the staining medium. While routine PAS staining reactions are followed by washing in running water to develop the red color seen with broad spectrum illumination, water development is unnecessary for the dye-tissue complex to fluoresce. The fluorescent emission peak and the maximum excitation peak of both developed and undeveloped pararosaniline-Schiff-reagent-tissue complexes are 645--50 nm and 540--45 nm, respectively. These spectral characteristics are not changed by binding to oxidation products of different glycoproteins or polysaccharides. Intense exposure to room light, but not 100 repetitive short (0.13 s) exposures, causes partial photodecomposition. Quantitative assessment of cytofluorescence requires definition of the optical system used to measure emission. In the microspectrophotometer employed in this study, dichroic mirrors reflect light with variable efficiency depending on wavelength from the light source to the stage, and variably block light reflected or emitted from the specimen, serving as crude barrier filters. These dichroic mirror characteristics are influenced by the exact nature of the optical coating on the surface of each individual mirror. Since the optical coating on the surface of each individual mirror. Since the optical coating of similar mirrors may vary, the properties of individual mirrors must be considered in the interpretation of spectral data and in determining the proper optical conditions for quantification of cytofluorescence.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 863749     DOI: 10.1007/bf00495809

Source DB:  PubMed          Journal:  Histochemistry        ISSN: 0301-5564


  13 in total

1.  Determination glycogen.

Authors:  R MONTGOMERY
Journal:  Arch Biochem Biophys       Date:  1957-04       Impact factor: 4.013

2.  Histological and histochemical uses of periodic acid.

Authors:  J F A McMANUS
Journal:  Stain Technol       Date:  1948-07

3.  On the binding of Schiff's reagent in the PAS reaction: effects of molecular configurations in models.

Authors:  H Puchtler; S N Meloan; B R Brewton
Journal:  Histochemistry       Date:  1974

4.  The periodate-Schiff reaction: specificity, kinetics, and reaction products with pure substrates.

Authors:  A Dahlqvist; I Olsson; A Nordén
Journal:  J Histochem Cytochem       Date:  1965 Jul-Aug       Impact factor: 2.479

5.  Irradiation of specimens by excitation light before and after staining with pararosaniline Feulgen: a new method to reduce non-specific fluorescence in cytofluorometry.

Authors:  S Fujita; M Fukuda
Journal:  Histochemistry       Date:  1974-06-26

6.  A microspectrofluorometer with epi-illumination operated under computer control.

Authors:  J S Ploem; J A De Sterke; J Bonnet; H Wasmund
Journal:  J Histochem Cytochem       Date:  1974-07       Impact factor: 2.479

7.  DNA cytofluorometry on large and small cell nuclei stained with pararosaniline Feulgen.

Authors:  S Fujita
Journal:  Histochemie       Date:  1973

8.  Fluorescence cytophotometry: a valuable method for the quantitative determination of nuclear Feulgen-DNA.

Authors:  N Böhm; E Sprenger
Journal:  Histochemie       Date:  1968

9.  An improved microspectrofluorimeter with automatic digital data logging: construction and operation.

Authors:  F W Rost; A G Pearse
Journal:  J Microsc       Date:  1971-10       Impact factor: 1.758

10.  A histochemical specific thionine-SO2 reagent and its use in a bicolor method for deoxyribonucleic acid and periodic acid Schiff positive substances.

Authors:  P VAN DUIJN
Journal:  J Histochem Cytochem       Date:  1956-01       Impact factor: 2.479

View more
  3 in total

1.  Reflection versus fluorescence: a note on the physical backgrounds of two types of light microscopy.

Authors:  M van der Ploeg; P van Duijn
Journal:  Histochemistry       Date:  1979-08

2.  Quantification of nuclear DNA and intracellular glycogen in a single cell by fluorescent double-staining.

Authors:  Y Tsuchihashi; K Nakanishi; M Fukuda; S Fujita
Journal:  Histochemistry       Date:  1979-10

3.  Transient expression of Wnt5a elicits ocular features of pseudoexfoliation syndrome in mice.

Authors:  Yong Yuan; Ursula Schlötzer-Schrehardt; Robert Ritch; Mindy Call; Fred B Chu; Fei Dong; Taylor Rice; Jianhua Zhang; Winston W-Y Kao
Journal:  PLoS One       Date:  2019-03-06       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.