Literature DB >> 8636559

Distribution of atrial electrogram types during atrial fibrillation: effect of rapid atrial pacing and intercaval junction ablation.

H Li1, J Hare, K Mughal, D Krum, M Biehl, S Deshpande, A Dhala, Z Blanck, J Sra, M Jazayeri, M Akhtar.   

Abstract

OBJECTIVES: This study examined the anatomic distribution types and possible determinant of atrial electrogram types during atrial fibrillation.
BACKGROUND: Different types of atrial electrograms during atrial fibrillation have been observed and classified, but their anatomic distribution patterns, determinants and potential usefulness in guiding future catheter ablation are unknown.
METHODS: Two animal models of atrial fibrillation were used: the sterile pericarditis model (n = 10) and the rapid atrial pacing model (400 beats/min for 6 weeks, n = 6). The atrial electrogram of atrial fibrillation and the atrial effective refractory period were obtained from multiple sites of the right and left atrium. In addition, decremental rapid atrial stimulation was applied to the site of shortest and longest atrial effective refractory periods until atrial fibrillation induction in a subgroup of nine dogs. Ablation of the intercaval junction was performed using the radiofrequency catheter technique in dogs with atrial fibrillation duration > 1 min.
RESULTS: In both models, organized atrial electrograms (type I) were predominantly observed at the left atrial sites and the right atrial appendage, whereas disorganized atrial electrograms (type III) were mainly observed at the right posterolateral atrium. The distribution of the atrial electrogram types closely followed that of the atrial effective refractory period, with the shortest atrial effective refractory period corresponding to organized atrial electrograms (type I) and the longest atrial effective refractory period corresponding to disorganized atrial electrograms (type III). The correlation of atrial electrogram type with the atrial effective refractory period was further demonstrated by the effect of rapid atrial stimulation. When rapid atrial stimulation was applied to the site with the shortest atrial effective refractory period, disorganized atrial electrograms were observed at sites with the longest atrial effective refractory period, whereas 1:1 atrial capture was still present at the stimulation site. Ablation of the intercaval junction made atrial fibrillation noninducible or tended to shorten the atrial fibrillation duration (from 26.4 +/- 24.2 to 8.8 +/- 22.6 min in the pericarditis group, p = 0.02, and from 33.7 +/- 29.2 to 12.1 +/- 23.8 min in the rapid pacing group, p = 0.09) but did not change the atrial electrogram types during atrial fibrillation.
CONCLUSIONS: Various types of atrial electrograms are present at different locations during atrial fibrillation. The atrial electrogram characteristics of atrial fibrillation at a specific location are related to the atrial effective refractory period, with short effective refractory periods associated with organized atrial electrograms and long effective refractory periods associated with disorganized electrograms.

Entities:  

Mesh:

Year:  1996        PMID: 8636559     DOI: 10.1016/0735-1097(96)00068-x

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  2 in total

1.  The spatial dispersion of atrial refractoriness and atrial fibrillation vulnerability.

Authors:  F X Roithinger; M R Karch; P R Steiner; A SippensGroenewegen; M D Lesh
Journal:  J Interv Card Electrophysiol       Date:  1999-12       Impact factor: 1.900

2.  Principal component analysis and cluster analysis for measuring the local organisation of human atrial fibrillation.

Authors:  L Faes; G Nollo; M Kirchner; E Olivetti; F Gaita; R Riccardi; R Antolini
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.