Literature DB >> 8635330

Continuous fiberoptic arterial and venous blood gas monitoring in hemorrhagic shock.

J M Oropello1, A Manasia, E Hannon, A Leibowitz, E Benjamin.   

Abstract

STUDY
OBJECTIVE: To compare the performance of continuous fiberoptic blood gas monitoring with standard, intermittent blood gas sampling in the measurement of arterial and central venous blood gases during marked hemodynamic changes.
DESIGN: Prospective, consecutive, enrollment, experimental study.
SETTING: Research laboratory at a university medical center. PARTICIPANTS: Seven anesthetized, mechanically ventilated pigs.
INTERVENTIONS: Severe shock was induced by hemorrhage in pigs monitored by a pulmonary artery catheter, an arterial line, and two fiberoptic blood gas sensors: one intra-arterial, and the other inserted into the superior vena cava via right internal jugular vein cutdown. Fiberoptic blood gas monitor measurements were compared with standard intermittent blood gas sampling. MEASUREMENTS AND
RESULTS: A total of 184 blood gas samples were compared in seven animals at baseline, during shock, and after resuscitation. The baseline mean (+/- 1 SD) cardiac output decreased from 4.0 +/- 0.9 to 1.2 +/- 0.6 L/min during shock and returned to baseline after retransfusion (3.9 +/- 1.3 L/min). The comparison of continuous fiberoptic blood gas monitoring with intermittent blood gas sampling showed a bias+/-precision of 0.035 +/- 0.047 for arterial pH, 0.021 +/- 0.031 for central venous pH, -4.09 +/- 2.96 mm Hg (-0.55 +/- 0.39 kPa) for arterial Pco2, -3.67 +/- 2.44 mm Hg (-0.49 +/- 0.3 3 kPa) for central venous Pco2, -5.79 +/- 9.64 mm Hg (-0.77 +/- 1.29 kPa) for arterial Po2, and -7.85 +/- 8.52 mm Hg (-1.05 +/- 1.14 kPa) for central venous Po2.
CONCLUSIONS: Continuous fiberoptic blood gas monitoring agrees closely with standard intermittent blood gas sampling during severe hemodynamic shifts and has a comparable accuracy for both arterial and venous blood gas measurements. Changes in venous Pco2 have recently been shown to correlate with changes in global tissue perfusion (eg, changes in cardiac output). Such data, available immediately via continuous venous blood gas monitoring, may be useful for monitoring shock and the response to resuscitation.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8635330     DOI: 10.1378/chest.109.4.1049

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  7 in total

1.  Monitoring the conjunctiva for carbon dioxide and oxygen tensions and pH during cardiopulmonary bypass.

Authors:  Irwin K Weiss; Sherwin J Isenberg; David L McArthur; Madeline Del Signore; John S McDonald
Journal:  J Extra Corpor Technol       Date:  2011-03

2.  Can venous base excess replace arterial base excess as a marker of early shock and a predictor of survival in trauma?

Authors:  Ramesh Wijaya; Jia Hui Ng; Lester Ong; Andrew Siang Yih Wong
Journal:  Singapore Med J       Date:  2016-02       Impact factor: 1.858

3.  Nitric oxide-releasing xerogel-based fiber-optic pH sensors.

Authors:  Kevin P Dobmeier; Gregory W Charville; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2006-11-01       Impact factor: 6.986

4.  Arterial vs venous blood gas differences during hemorrhagic shock.

Authors:  Kristopher Burton Williams; Ashley Britton Christmas; Brant Todd Heniford; Ronald Fong Sing; Joseph Messick
Journal:  World J Crit Care Med       Date:  2014-05-04

Review 5.  Monitoring with In Vivo Electrochemical Sensors: Navigating the Complexities of Blood and Tissue Reactivity.

Authors:  Pankaj Vadgama
Journal:  Sensors (Basel)       Date:  2020-06-02       Impact factor: 3.576

6.  Diagnostic value of intravenous oxygen saturation compared with arterial and venous base excess to predict hemorrhagic shock in multiple trauma patients.

Authors:  Ali Taherinia; Ghazal Saba; Mohsen Ebrahimi; Koorosh Ahmadi; Zabihollah Taleshi; Peyman Khademhosseini; Ali Soltanian; Atie Safaee; Mehran Bahramian; Shahin Gharakhani; Mohammad Ali Jafari Nodoshan
Journal:  J Family Med Prim Care       Date:  2021-07-30

7.  Assessment of a Non-Invasive Brain Oximeter in a Sheep Model of Acute Brain Injury.

Authors:  Barry Dixon; Renee Turner; Chris Christou
Journal:  Med Devices (Auckl)       Date:  2019-12-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.