Literature DB >> 8633452

Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta.

M R Prince1, D L Narasimham, W T Jacoby, D M Williams, K J Cho, M V Marx, G M Deeb.   

Abstract

OBJECTIVE: Our objective was to evaluate image quality and preliminary clinical experience with three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta. SUBJECTS AND METHODS: Ninety patients with suspected thoracic aorta pathology underwent 97 MR examinations at 1.5 T with a 4-min, three-dimensional spoiled gradient-echo techniques. Gadolinium infusion was timed for maximum arterial contrast during acquisition of the central portion of K-space. No ECG gating or breath-holding was used. All MR examinations were evaluated retrospectively for intravascular signal-to-noise ratio (SNR). In 30 of the 90 patients, results from surgery (n = 11), angiography (n = 12), or both (n = 7) were available. Four radiologists who were unaware of the angiographic or surgical findings assessed each of these 30 examinations for three types of pathology: dissection, coarctation, or aneurysm. The observers also assessed aortic branch vessel patency and vascular anomalies in the 19 patients who had angiographic correlation.
RESULTS: Image quality (determined as SNR) was highest in the aortic arch, upper descending thoracic aorta, and upper abdominal aorta. We saw a small reduction in the SNR in the ascending aorta and lower descending thoracic aorta (p < .0001), attributable to cardiac and respiratory motion. Image quality was not affected by slow flow. MR imaging correctly diagnosed pathology in all 30 patients with angiographic or surgical correlation, including eight dissections, three coarctations, and 10 aneurysms. The type of the dissection was correctly determined in all eight patients. Stenoses of major branch vessel origins were detected with a sensitivity of 90% (95% bayesian confidence interval, 99-63%) and a specificity of 96% (95% bayesian confidence interval, 99-89%) in the 19 patients with angiographic correlation. Five vascular anomalies, including an aberrant right subclavian artery, a bovine arch, and three accessory renal arteries, were correctly identified.
CONCLUSION: Three-dimensional gadolinium-enhanced MR angiography has the potential to accurately diagnose aortic dissection, coarctation, and aneurysm. It does not require ECG gating or breath-holding and thereby extends the diagnostic utility of MR imaging for the thoracic aorta.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8633452     DOI: 10.2214/ajr.166.6.8633452

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  31 in total

1.  Gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries with multiple bolus injection: scan optimization in vitro and in vivo.

Authors:  J J Westenberg; M N Wasser; R J van der Geest; P M Pattynama; A de Roos; J Vanderschoot; J H Reiber
Journal:  Int J Card Imaging       Date:  1999-04

Review 2.  Breathhold cardiac MRI and MRA.

Authors:  G G Hartnell
Journal:  Int J Card Imaging       Date:  1999-04

Review 3.  Current concepts in the evaluation of vascular disease: magnetic resonance and computed tomographic angiography.

Authors:  B D Toombs; J M Jing
Journal:  Tex Heart Inst J       Date:  2000

4.  Transforming growth factor-beta(1) expression in dilated cardiomyopathy.

Authors:  J E Sanderson; K B Lai; I O Shum; S Wei; L T Chow
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

5.  Idiopathic dilated cardiomyopathy: lack of association with haemochromatosis gene in the CARDIGENE study.

Authors:  G Hetet; B Grandchamp; C Bouchier; V Nicaud; L Tiret; G Roizès; M Desnos; K Schwartz; R Dorent; M Komajda
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

6.  Contrast enhanced magnetic resonance angiography and pulmonary venous anomalies.

Authors:  F Godart; S Willoteaux; C Rey; B Cocheteux; C Francart; J P Beregi
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

7.  Effects of cardiac resynchronisation on maximal and submaximal exercise performance in advanced heart failure patients with conduction abnormality.

Authors:  D Birnie; L P Soucie; S Smith; A S Tang
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

8.  Reciprocal increase of circulating interleukin-10 and interleukin-6 in patients with acute myocardial infarction.

Authors:  N Kotajima; T Kimura; T Kanda; A Kuwabara; Y Fukumura; M Murakami; I Kobayashi
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

9.  Percutaneous aortic valve replacement: will we get there?

Authors:  Y Boudjemline; P Bonhoeffer
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

10.  Tetrahydrobiopterin attenuates cholesterol induced coronary hyperreactivity to endothelin.

Authors:  S Verma; A S Dumont; A Maitland
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.