Literature DB >> 8627899

Duplex velocity characteristics of aortoiliac stenoses.

A A de Smet1, E J Ermers, P J Kitslaar.   

Abstract

PURPOSE: It is now possible to grade aortoiliac stenoses in broad categories based on peak systolic velocity (PSV) changes. The goal of this study was to see whether additional simple Doppler parameters would improve the grading of aortoiliac obstructive disease.
METHODS: Duplex parameters were compared in 112 aortoiliac segments with four categories of arteriographic diameter reduction and four categories of common femoral artery pressure measurements. These parameters were PSV, PSV ratio, PSV difference, end diastolic velocity (EDV), the presence or absence of reverse flow, and the presence or absence of spectral broadening.
RESULTS: The discriminative value of the PSV ratio was better than that of either the absolute PSV value or the PSV difference. A PSV ratio < 1.5 combined with reverse flow and a clear systolic window in the Doppler spectrum predicted a diameter reduction < 20% (sensitivity, 100%; specificity, 58%; positive predictive value [PPV], 89%; negative predictive value [NPV], 100%; accuracy, 90%). For the detection of > or = 50% aortoiliac stenoses, a PSV ratio > or = 2.8 provided 86% sensitivity and 84% specificity (PPV, 84%; NPV, 85%, accuracy, 85%). An absolute PSV value of 200 cm/sec has a high sensitivity (95%) but a low specificity (55%) in identifying > or = 50% stenoses (PPV, 68%; NPV, 91%; accuracy 75%). An EDV > 0 cm/sec at the stenosis indicates a femorobrachial pressure index < 0.90 with 51% sensitivity and 89% specificity. An EDV > or = 40 cm/sec indicates a femorobrachial index < 0.80 with 50% sensitivity and 89% specificity, and indicates > or = 75% arteriographic stenoses with 70% sensitivity and 90% specificity (PPV, 64%; NPV, 92%; accuracy, 86%). A stenosis > or = 75% was also identified by a PSV ratio of 5.0 with 65% sensitivity and 91% specificity (PPV, 65%; NPV, 91%; accuracy, 86%).
CONCLUSIONS: The PSV ratio is the most important parameter to grade aortoiliac stenoses into < 20%, 20% to 49%, 50% to 74%, and 75% to 99% categories, but additional parameters such as absolute PSV value, EDV, and the presence or absence of reverse flow and spectral broadening in the Doppler spectrum are helpful in gradation.

Entities:  

Mesh:

Year:  1996        PMID: 8627899     DOI: 10.1016/s0741-5214(96)80043-7

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  7 in total

Review 1.  Multimodality imaging of lower extremity peripheral arterial disease: current role and future directions.

Authors:  Amy W Pollak; Patrick T Norton; Christopher M Kramer
Journal:  Circ Cardiovasc Imaging       Date:  2012-11       Impact factor: 7.792

2.  Duplex Analysis of Cannulated Vessels in Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation.

Authors:  Jorik Simons; Sandra Agricola; Jeroen Smets; Renske Metz; Silvia Mariani; Marie-José Vleugels; Reinier R Smeets; Walther N K A van Mook; Barend Mees; Roberto Lorusso
Journal:  Medicina (Kaunas)       Date:  2022-05-18       Impact factor: 2.948

3.  Echocardiographic evaluation of aorto-iliac occlusive disease.

Authors:  Grzegorz Styczynski; Cezary Szmigielski; Anna Kaczynska; Jerzy Leszczynski; Grzegorz Rosinski; Agnieszka Kuch-Wocial
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-19       Impact factor: 2.357

4.  Analysis of peripheral artery velocity tracing in a porcine model.

Authors:  Qingxin Meng; Weiwei Ding; Bin Yang; Ninghua Fu; Guangming Lu
Journal:  Radiol Oncol       Date:  2011-03-15       Impact factor: 2.991

5.  Exercise transcutaneous oxygen pressure measurement has good sensitivity and specificity to detect lower extremity arterial stenosis assessed by computed tomography angiography.

Authors:  Caroline Koch; Emmanuel Chauve; Ségolène Chaudru; Alexis Le Faucheur; Vincent Jaquinandi; Guillaume Mahé
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

6.  Accuracy of Acceleration Time of Distal Arteries to Diagnose Severe Peripheral Arterial Disease.

Authors:  Jean-Eudes Trihan; Guillaume Mahé; Magali Croquette; Vicky Coutant; Cécile Thollot; Jérôme Guillaumat; Damien Lanéelle
Journal:  Front Cardiovasc Med       Date:  2022-01-20

7.  ABPI against Colour Duplex Scan: A Screening Tool for Detection of Peripheral Arterial Disease in Low Resource Setting Approach to Validation.

Authors:  Janaka Weragoda; Rohini Seneviratne; Manuj C Weerasinghe; S M Wijeyaratne
Journal:  Int J Vasc Med       Date:  2016-03-10
  7 in total