Literature DB >> 8623623

Gantry angulation in CT-guided percutaneous adrenal biopsy.

S Hussain1.   

Abstract

OBJECTIVE: This study was performed to test a new method for CT-guided adrenal biopsy using angulation of the CT gantry.
MATERIALS AND METHODS: In 23 patients, 26 biopsies were performed on patients in the prone position using CT gantry angulation and the introduction of the biopsy needles along the same angle, guided by the gantry locating light. The use of angulation ensured a safe needle path that avoided vital structures, such as the pleura, while monitoring of the needle course and its tip on one or two CT slices.
RESULTS: Twenty-two of 23 adrenal masses (96%) were successfully biopsied without complications. Fifteen (65%) of the target masses were 1.5 cm or smaller.
CONCLUSION: Using an angled gantry during percutaneous biopsy is a safe and preferred method over other techniques for biopsy of adrenal masses and can be used easily for small adrenal masses.

Entities:  

Mesh:

Year:  1996        PMID: 8623623     DOI: 10.2214/ajr.166.3.8623623

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.

Authors:  J Webster Stayman; Sarah Capostagno; Grace J Gang; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-02

2.  Tilting the gantry for CT-guided spine procedures.

Authors:  Daniel J Boulter; Zoran Rumboldt; Giuseppe Bonaldi; Mario Muto; Alessandro Cianfoni
Journal:  Radiol Med       Date:  2014-02-15       Impact factor: 3.469

Review 3.  Image-guided adrenal and renal biopsy.

Authors:  Karun V Sharma; Aradhana M Venkatesan; Daniel Swerdlow; Daniel DaSilva; Avi Beck; Nidhi Jain; Bradford J Wood
Journal:  Tech Vasc Interv Radiol       Date:  2010-06

4.  CT-guided adrenal biopsy: comparison of ipsilateral decubitus versus prone patient positioning for biopsy approach.

Authors:  Bruno C Odisio; Alda L Tam; Rony Avritscher; Sanjay Gupta; Michael J Wallace
Journal:  Eur Radiol       Date:  2012-01-08       Impact factor: 5.315

5.  Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results.

Authors:  Philipp Bruners; Tobias Penzkofer; Markus Nagel; Robert Elfring; Nina Gronloh; Thomas Schmitz-Rode; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2008-11-29       Impact factor: 5.315

6.  3D cone-beam CT guidance, a novel technique in renal biopsy--results in 41 patients with suspected renal masses.

Authors:  Sicco J Braak; Harm H E van Melick; Mircea G Onaca; Johannes P M van Heesewijk; Marco J L van Strijen
Journal:  Eur Radiol       Date:  2012-06-02       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.