Literature DB >> 8621038

Shear bond strength of four commercial bonding systems to cp Ti.

A Fujishima1, Y Fujishima, J L Ferracane.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the bond strength of veneering composite to commercially pure titanium (cp Ti) using several different bonding systems and a post-cure heat treatment.
METHODS: Four commercial bonding systems (Cesead, Kuraray; New Metacolor, Sun Medical; Silicaoater MD, Kulzer; Termoresin LC II, GC) were evaluated. Bonding was attempted with the opaque resin provided by each bonding system as well as with the New Metacolor opaque resin. New Metacolor resin composite was used for the veneering composite. Half of the specimens were subjected to a post-cure heat treatment at 100 degrees C for 30 min. The shear bond strengths were tested after aging the specimens in water at 37 degrees C for 1 d and also after thermocycling for 16.5 d (20,000 cycles).
RESULTS: Strong bonds, exceeding 20 MPa, were achieved with all of the bonding systems with the exception of Thermoresin LC II, which is designed for noble metals. Bond strengths were only increased by the post-cure heat treatment for the New Metacolor system. Thermocycling caused a significant reduction in bond strength for the New Metacolor adn the Thermoresin LC II systems. The use of the New Metacolor opaque resin produced increased bonding for the Silicoater MD and the opaque resin produced increased bonding for the Silicoater MD and the Cesead systems, but the effect was eliminated after thermocycling. SIGNIFICANCE: Strong, durable bonds can be achieved between composite and sandblasted cp Ti, thus enhancing the usefulness of this metal for esthetic resin-veneered crowns and other fixed prosthetics.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8621038     DOI: 10.1016/0109-5641(95)80038-7

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  3 in total

1.  Resistance to cyclic loading of teeth restored with posts.

Authors:  A Sahafi; A Peutzfeldt; G Ravnholt; E Asmussen; K Gotfredsen
Journal:  Clin Oral Investig       Date:  2005-03-04       Impact factor: 3.573

2.  Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy.

Authors:  Su-Sung Kim; Mong-Sook Vang; Hong-So Yang; Sang-Won Park; Hyun-Pil Lim
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

3.  Factors affecting the bond strength of denture base and reline acrylic resins to base metal materials.

Authors:  Naomi Tanoue; Yasuhiro Matsuda; Hiroaki Yanagida; Hideo Matsumura; Takashi Sawase
Journal:  J Appl Oral Sci       Date:  2013 Jul-Aug       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.