Silicone stents in the management of benign tracheobronchial stenoses. Tolerance and early results in 63 patients.

J I Martinez-Ballarin1, J P Diaz-Jimenez, M J Castro, J A Moya.   

Abstract

STUDY
OBJECTIVE: To assess tolerance and early results of Dumon silicone stents inserted in patients with nonneoplastic airway obstruction.
DESIGN: Tracheobronchial stenting for palliative or curative restoration of airway narrowing has been evaluated in a retrospective study.
SETTING: Tertiary-referral teaching hospital. PATIENTS: Between May 1991 and September 1994, 64 patients with a mean age of 52 years had endobronchial silicone stent insertion for benign tracheal stenosis (82% secondary to intubation or tracheostomy injury). Lesions were pure fibrous stenosis in 25 patients and fibroinflammatory stenosis in 38. Prostheses were used for temporary stenting of the airway during 18 months in 48 patients in whom cure was expected and as a procedure for palliation in the remaining 15 patients.
INTERVENTIONS: In all cases, the Dumon tracheobronchial stent was implanted with the rigid bronchoscope under general anesthesia.
RESULTS: Five patients died (four from unrelated causes); one was due to hypersecretion and airway obstruction at the time of an emergency tracheostomy 20 days after stent insertion. Complications included migration of prostheses in 11 (17.5%) patients, granuloma formation in 4 (6.3%) patients, and airway obstruction due to heavy secretion in 4 (6.3%). In 48 patients who received silicone stents with curative expectations, removal of the device was accomplished in 21 patients. Therapy proved successful in 17 patients with a mean follow-up of 259+/- 173 days and stenosis recurred in 4. In 16 patients, stents still remain for a mean period of 364+/-119 days. In the series of 15 patients in whom silicon stents were implanted for palliation, prostheses were placed permanently in 11 with a mean follow-up of 486+/-260 days. In the remaining four patients with tracheostomy, silicone stents were used after inability to expand the upper limb of the T-tube (two patients) or placed above the tracheostomy stoma to maintain laryngotracheal patency and preserve phonation when a T-tube was poorly tolerated (two patients).
CONCLUSIONS: Silicone tracheobronchial stents are effective in the maintenance of airway patency and are associated with good tolerance and infrequent complications that are rarely life-threatening.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8617068     DOI: 10.1378/chest.109.3.626

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  37 in total

1.  The role of airway stent placement in the management of tracheobronchial stenosis caused by inoperable advanced lung cancer.

Authors:  Kinya Furukawa; Junzo Ishida; Gaku Yamaguchi; Jitsuo Usuda; Hidemitsu Tsutsui; Makoto Saito; Chimori Konaka; Harubumi Kato
Journal:  Surg Today       Date:  2010-03-26       Impact factor: 2.549

2.  [Segmental tracheal resection for the treatment of tracheal stenoses].

Authors:  M Weidenbecher; M Weidenbecher; H Iro
Journal:  HNO       Date:  2007-01       Impact factor: 1.284

Review 3.  Tracheobronchial tuberculosis.

Authors:  Vikas Pathak; Ray W Shepherd; Samira Shojaee
Journal:  J Thorac Dis       Date:  2016-12       Impact factor: 2.895

4.  Radiation-associated airway necrosis.

Authors:  Abdul Hamid Alraiyes; M Chadi Alraies; Abbas Abbas
Journal:  Ochsner J       Date:  2013

Review 5.  Stents for airway strictures: selection and results.

Authors:  Adil Ayub; Adnan M Al-Ayoubi; Faiz Y Bhora
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

6.  Application of the Montgomery T-tube in subglottic tracheal benign stenosis.

Authors:  Huihui Hu; Jisong Zhang; Fengjie Wu; Enguo Chen
Journal:  J Thorac Dis       Date:  2018-05       Impact factor: 2.895

Review 7.  Techniques of endoscopic airway tumor treatment.

Authors:  Nicolas Guibert; Laurent Mhanna; Sylvain Droneau; Gavin Plat; Alain Didier; Julien Mazieres; Christophe Hermant
Journal:  J Thorac Dis       Date:  2016-11       Impact factor: 2.895

8.  First-line tracheal resection and primary anastomosis for postintubation tracheal stenosis.

Authors:  H Elsayed; A M Mostafa; S Soliman; T Shoukry; A A El-Nori; H Y El-Bawab
Journal:  Ann R Coll Surg Engl       Date:  2016-05-03       Impact factor: 1.891

9.  Thermoforming of tracheal cartilage: viability, shape change, and mechanical behavior.

Authors:  Yongseok Chae; Dmitriy Protsenko; Paul K Holden; Cara Chlebicki; Brian J F Wong
Journal:  Lasers Surg Med       Date:  2008-10       Impact factor: 4.025

10.  A Dumon stent inserted for bronchial stenosis causing a left bronchopericardial fistula: report of a case.

Authors:  S Sugiyama; S Koyama; A Murakami; Y Mizushima; T Misaki; K Matsui; M Kitagawa
Journal:  Surg Today       Date:  1998       Impact factor: 2.549