Literature DB >> 8615257

Detection of main renal artery stenosis using phase-contrast cine MR angiography.

J M Silverman1, M L Friedman, R J Van Allan.   

Abstract

OBJECTIVE: The purpose of our study was to assess the ability of phase-contrast cine MR angiography to detect the presence of main renal artery stenosis. SUBJECTS AND METHODS: We prospectively evaluated 75 hypertensive patients form main renal artery stenosis using phase-contrast cine MR angiography. Each main renal artery was evaluated as normal or abnormal. Thirty-seven of the 75 patients underwent conventional arteriography or intraarterial digital subtraction arteriography; these results were compared with the MR angiographic interpretations. Only those patients who had confirmatory arteriography were included in the statistical analysis.
RESULTS: Thirty-six main renal arteries interpreted as normal by MR angiography were found to be without a focal stenosis on invasive arteriography. MR angiography suggested 32 main renal artery stenoses; invasive arteriography showed 29 of these as stenoses. Three main renal arteries that were interpreted as having focal stenoses by MR angiography were shown to be not stenotic by invasive arteriography. Three other patients had diffusely narrowed main renal arteries bilaterally without a focal stenosis on MR angiography; bilateral proximal renal artery stenoses were seen at arteriography in two of these patients, and diffusely narrowed main renal arteries were seen in the third patient. Thus, the sensitivity of phase-contrast cine MR angiography for detecting a focal stenosis or abnormal main renal artery was 100% (95% confidence interval, 88-100%) and the specificity was 93% (95% confidence interval, 80-99%). The kappa coefficient was 0.85 with a standard error of 0.08.
CONCLUSION: Phase-contrast cine MR angiography had a high degree of accuracy and a high negative predictive value in detecting the presence of main renal artery stenoses and may be a good screening technique for renovascular hypertension.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8615257     DOI: 10.2214/ajr.166.5.8615257

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Non-contrast MRA using an inflow-enhanced, inversion recovery SSFP technique in pediatric abdominal imaging.

Authors:  Suraj Serai; Alexander J Towbin; Daniel J Podberesky
Journal:  Pediatr Radiol       Date:  2011-11-10

Review 2.  Advanced imaging techniques in pediatric body MRI.

Authors:  Jesse Courtier; Anil G Rao; Sudha A Anupindi
Journal:  Pediatr Radiol       Date:  2017-04-13

3.  Phase-contrast MRI evaluation of haemodynamic changes induces by a coeliac axis stenosis in the gastroduodenal artery.

Authors:  Audrey Haquin; Monica Sigovan; Salim Si-Mohamed; Jean-Yves Mabrut; Anne-Frédérique Manichon; Melisa Bakir; Agnès Rode; Loïc Boussel
Journal:  Br J Radiol       Date:  2017-03-03       Impact factor: 3.039

4.  A 3D balanced-SSFP Dixon technique with group-encoded k-space segmentation for breath-held non-contrast-enhanced MR angiography.

Authors:  Manojkumar Saranathan; Ersin Bayram; Pauline W Worters; James F Glockner
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

Review 5.  MRI of the kidney-state of the art.

Authors:  J J Nikken; G P Krestin
Journal:  Eur Radiol       Date:  2007-07-24       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.