Literature DB >> 8613607

Effects of intraaortic balloon pumping on septal arterial blood flow velocity waveform during severe left main coronary artery stenosis.

A Kimura1, E Toyota, S Lu, M Goto, T Yada, Y Chiba, J Ebata, H Tachibana, Y Ogasawara, K Tsujioka, F Kajiya.   

Abstract

OBJECTIVES: We sought to evaluate the effect of intraaortic balloon pumping on the phasic blood velocity waveform into myocardium with severe coronary artery stenosis.
BACKGROUND: In the presence of severe coronary artery stenosis, it is not clear whether intraaortic balloon pumping augments intramyocardial inflow during diastole or changes systolic retrograde blood flow from the myocardium to the extramural coronary arteries.
METHODS: Using anesthetized open chest dogs (n=7), we introduced severe stenosis in the left main coronary artery to reduce the poststenotic pressure to approximately 60 mm Hg (>90% diameter stenosis). Septal arterial blood flow velocities were measured with a 20-MHz, 80-channel ultrasound pulsed Doppler velocimeter. Left anterior descending arterial flow, aortic pressure and poststenotic distal coronary pressure were measured simultaneously. The diastolic anterograde flow integral and systolic retrograde flow integral were compared in the presence and absence of intraaortic balloon pumping.
RESULTS: Although intraaortic balloon pumping augmented diastolic aortic pressure, this pressure increase was not effectively transmitted through stenosis. Septal arterial diastolic flow velocity was not augmented, and left anterior descending arterial flow was unchanged during intraaortic balloon pumping.
CONCLUSIONS: In the presence of severe coronary artery stenosis, intraaortic balloon pumping failed to increase diastolic inflow in the myocardium and did not enhance systolic retrograde flow from the myocardium to the extramural coronary artery. Thus, the major effect of intraaortic balloon pumping on the ischemic heart with severe coronary artery stenosis may be achieved by reducing oxygen demand by systolic unloading.

Entities:  

Mesh:

Year:  1996        PMID: 8613607     DOI: 10.1016/0735-1097(95)00561-7

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

1.  IABP plus ECMO-Is one and one more than two?

Authors:  Sebastian Nuding; Karl Werdan
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

2.  Preserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation.

Authors:  Hiroyuki Nakajima; Atsushi Iguchi; Mimiko Tabata; Masaru Kambe; Masahiro Ikeda; Kazuhiko Uwabe; Toshihisa Asakura; Hiroshi Niinami
Journal:  J Cardiothorac Surg       Date:  2016-11-28       Impact factor: 1.637

3.  How much of the intraaortic balloon volume is displaced toward the coronary circulation?

Authors:  Christina Kolyva; George M Pantalos; John R Pepper; Ashraf W Khir
Journal:  J Thorac Cardiovasc Surg       Date:  2010-01-18       Impact factor: 5.209

4.  Intraoperative intra-aortic balloon pump improves 30-day outcomes of patients undergoing extensive coronary endarterectomy.

Authors:  Zhen Wu; Changcheng Liu; Ying Fang; Hua Wei; Chengxiong Gu
Journal:  J Cardiothorac Surg       Date:  2020-08-20       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.