Literature DB >> 8613600

Stents for intracoronary placement: current status and future directions.

E Eeckhout1, L Kappenberger, J L Goy.   

Abstract

The technique of intracoronary stenting has achieved remarkable progress over the last few years. Improved stent deployment techniques and optimization of postprocedural management have dramatically improved the safety of intracoronary stent placement. At present, the incidence of early vessel closure after stenting is even lower than that after standard angioplasty and, as most operators no longer prescribe aggressive anticoagulation, bleeding complications are uncommon. Stenting has become an extremely effective treatment for abrupt or threatened vessel closure or for any suboptimal angiographic result during conventional angioplasty. Furthermore, large prospective trials have demonstrated that its efficacy is superior to that of conventional angioplasty for primary restenosis prevention in focal lesions of some native coronary arteries. Ongoing trials tend to extrapolate these conclusions to saphenous vein graft lesions. Mechanical support of the vessel wall explains the sustained angiographic benefit observed after stenting. Future developments may include the use of stents as a vehicle for local drug delivery in an attempt to further reduce the incidence of restenosis. In view of these results, coronary stents should be considered a new standard therapeutic modality in interventional cardiology.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8613600     DOI: 10.1016/0735-1097(95)00548-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

1.  Long-term prognostic value of exercise 99mTc-MIBI SPET myocardial perfusion imaging in patients after percutaneous coronary intervention.

Authors:  Xiaoli Zhang; Xiujie Liu; Zuo-Xiang He; Rongfang Shi; Minfu Yang; Runlin Gao; Jilin Chen; Yuejin Yang; Wei Fang
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-22       Impact factor: 9.236

2.  Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications.

Authors:  M Haïdopoulos; S Turgeon; C Sarra-Bournet; G Laroche; D Mantovani
Journal:  J Mater Sci Mater Med       Date:  2006-07       Impact factor: 4.727

Review 3.  Coronary Stents: History, Design, and Construction.

Authors:  Torrey Schmidt; J Dawn Abbott
Journal:  J Clin Med       Date:  2018-05-29       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.