Gamma camera-based clearance techniques which use the renal uptake ratio (RUR) of the radiotracer are available to estimate the effective renal plasma flow (ERPF) and glomerular filtration rate. To evaluate the accuracy of these techniques, we measured RUR by an optimized procedure and compared it with standard ERPF. Iodine-123 orthoiodohippurate (OIH) scintigraphy and simultaneous para-aminohippurate clearance study for measuring standard ERPF were performed in three hospitals in 24 patients with normal or mildly impaired renal function. 123I-OIH was injected intravenously and 10-s consecutive imaging of the kidneys was started when the abdominal aorta was seen. The attenuation coefficient for 123I was measured in each hospital using the same water-equivalent absorption materials and used for the attenuation correction. After subtracting background radioactivity, RURs were defined as the count ratios of fractional renal uptakes based on the integral from 1 to 2, 2 to 3, 1.5 to 2.5 and 1 to 3 min after the injection of 123I-OIH in relation to injected doses using the following three procedures in respect of attenuation correction: (1) RUR without attenuation correction, (2) RUR with fractional renal uptake corrected by the measured attenuation coefficient, (3) RUR with the total injected dose corrected by the absorption material. To decide upon the appropriate correction method and time interval, RURs were compared with standard ERPF. Among the three correction methods, procedure 2 showed the highest correlation between RUR and standard ERPF, but the correlation coefficient was low (r=0.75). No significant difference was observed among the RURs of each time interval. Individual kidney function measured from early renal uptake may be inaccurate even when appropriate correction is made for attenuation, background activity or time lag between injection and data acquisition. Gamma camera-based measurement of renal function using 123I-OIH is limited with regard to accuracy and reproducibility, though it is convenient and non-invasive.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8612655     DOI: 10.1007/bf01247363

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  23 in total

1.  Letter: The preparation of iodine-123 labelled sodium ortho-iodo hippurate and its clearance by the rat kidneys.

Authors:  M L Thakur; B M Chauser; R F Hudson
Journal:  Int J Appl Radiat Isot       Date:  1975-05

2.  Preparation and use of I 131 labeled sodium iodohippurate in kidney function tests.

Authors:  M TUBIS; E POSNICK; R A NORDYKE
Journal:  Proc Soc Exp Biol Med       Date:  1960-03

3.  [A new flexible water-equivalent material (author's transl)].

Authors:  I Yonome
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  1976

4.  Quantitative determination of kidney function using radiorenography.

Authors:  A Fritjofsson; J E Persson; B Söderholm; K J Vikterlöf
Journal:  Scand J Urol Nephrol       Date:  1973

5.  The normal renogram. A. Compartment analysis of the radiorenogram and kinetics of 131 -I hippuran.

Authors:  M D Blaufox
Journal:  Prog Nucl Med       Date:  1972

6.  [Estimation of glomerular filtration rate from fractional renal uptake of 99mTc-DTPA].

Authors:  T Ito; K Takeda; S Toyota; H Maeda; T Kitano; T Nakagawa; N Yamaguchi
Journal:  Kaku Igaku       Date:  1984-12

7.  Kidney depth measurement and its influence on quantitation of function from gamma camera renography.

Authors:  S M Gruenewald; L T Collins; R M Fawdry
Journal:  Clin Nucl Med       Date:  1985-06       Impact factor: 7.794

8.  Rapid method for the measurement of differential renal function: validation.

Authors:  A Chachati; A Meyers; J P Godon; P Rigo
Journal:  J Nucl Med       Date:  1987-05       Impact factor: 10.057

9.  New formulas for the calculation of effective renal plasma flow.

Authors:  W N Tauxe; E V Dubovsky; T Kidd; F Diaz; L R Smith
Journal:  Eur J Nucl Med       Date:  1982

10.  Measurement of skin-to-kidney distance in children: implications for quantitative renography.

Authors:  D C Maneval; H L Magill; A M Cypess; J H Rodman
Journal:  J Nucl Med       Date:  1990-03       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.