Literature DB >> 8611283

The variation of integrated backscatter in human hearts in differing ultrasonic transthoracic views.

A Lange1, C M Moran, P Palka, L N Fenn, G R Sutherland, W N McDicken.   

Abstract

It has been shown previously that in normal subjects the interventricular septum imaged in the long-axis view (LAX) and the left ventricular posterior wall imaged in both the LAX and the short-axis view (SAX) exhibit cyclic variation of integrated backscatter (IB) throughout the cardiac cycle, with maximum values occurring at end diastole (ED) and minimum at end systole (ES). The ability to demonstrate this cyclic variation within these myocardial regions in only two ultrasonic views has limited the potential clinical utility of an IB imaging system. To determine whether clinically useful information on the variation of IB is available from different myocardial regions in different ultrasonic views, we measured ED to ES variation of IB from the parasternal and apical views in normal subjects with a radiofrequency acquisition technique. Two independent clinical observers analyzed ED to ES variation of IB from 14 normal volunteers (mean age 32 +/- 6 years; range 21 to 45 years) in reconstructed two-dimensional ultrasonic images obtained from the parasternal LAX and SAX and apical two-chamber (2C) and four-chamber (4C) views. ED to ES variation of IB was measured from manually traced regions of interest (ROI) within the myocardium. These ROIs were chosen interactively and were located within the midposterior wall and the midanteroseptum in LAX views; within the midposterior wall, midanteroseptum, midseptum, and midlateral wall in SAX views; within the midseptum and the midlateral wall in 4C views; and within the midinferior wall and the midanterior wall 2C views. In all analyzed ROIs within the parasternal and apical views, ED to ES variation of IB was found. We have shown that the maximum magnitude of IB was at ES within the midseptum and in 10 out of 14 volunteers in the midanteroseptum measured from SAX views, the midanterior wall from 2C views, and the midlateral wall from 4C views. The rest of the ROIs analyzed exhibited the maximum value of IB cyclic variation at ED. We have confirmed that the ED to ES variation of IB is present not only when measured from the two standard parasternal views but also from the two apical views in all analyzed myocardial walls, and the minimum of this cyclic variation was not always coincident with ES nor the maximum with ED.

Entities:  

Mesh:

Year:  1995        PMID: 8611283     DOI: 10.1016/s0894-7317(05)80007-0

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  8 in total

Review 1.  Developments in cardiovascular ultrasound. Part 3: Cardiac applications.

Authors:  C M Moran; W N McDicken; P R Hoskins; P J Fish
Journal:  Med Biol Eng Comput       Date:  1998-09       Impact factor: 2.602

2.  Ultrasonic tissue characterization in patients with dilated cardiomyopathy: comparison with findings from right ventricular endomyocardial biopsy.

Authors:  S Fujimoto; R Mizuno; Y Nakagawa; A Kimura; K Yamaji; C Yutani; K Dohi; H Nakano
Journal:  Int J Card Imaging       Date:  1999-10

Review 3.  New technology in echocardiography II: imaging techniques.

Authors:  W N McDicken; C M Moran; P R Hoskins; M J Monaghan; G R Sutherland
Journal:  Heart       Date:  1996-06       Impact factor: 5.994

4.  Myocardial ultrasonic tissue characterization in patients with thyroid dysfunction.

Authors:  Minna M D Romano; Léa M Z Maciel; Oswaldo C Almeida-Filho; Antonio Pazin-Filho; André Schmidt; Benedito C Maciel
Journal:  Cardiovasc Ultrasound       Date:  2010-04-23       Impact factor: 2.062

5.  Nonalcoholic fatty liver disease is associated with hepatic and skeletal muscle insulin resistance in overweight adolescents.

Authors:  Sheela Deivanayagam; B Selma Mohammed; Bernadette E Vitola; Gihan H Naguib; Tamir H Keshen; Erik P Kirk; Samuel Klein
Journal:  Am J Clin Nutr       Date:  2008-08       Impact factor: 7.045

6.  Use of myocardial backscatter as a quantitative tool for dobutamine echocardiography: feasibility, response to ischemia and accuracy compared with coronary angiography.

Authors:  Jared Dart; Satoshi Yuda; Peter Cain; Colin Case; Thomas H Marwick
Journal:  Int J Cardiovasc Imaging       Date:  2002-10       Impact factor: 2.357

Review 7.  Cancer therapy and cardiotoxicity: the need of serial Doppler echocardiography.

Authors:  Maurizio Galderisi; Francesco Marra; Roberta Esposito; Vincenzo Schiano Lomoriello; Moira Pardo; Oreste de Divitiis
Journal:  Cardiovasc Ultrasound       Date:  2007-01-25       Impact factor: 2.062

8.  Early detection of doxorubicin myocardial injury by ultrasonic tissue characterization in an experimental animal model.

Authors:  Minna Moreira Dias Romano; Antônio Pazin-Filho; João Lucas O'Connel; Marcus Vinícius Simões; André Schmidt; Érica C Campos; Marcos Rossi; Benedito Carlos Maciel
Journal:  Cardiovasc Ultrasound       Date:  2012-10-10       Impact factor: 2.062

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.