Literature DB >> 8611281

Evaluation of a semiautomatic contour detection approach in sequences of short-axis two-dimensional echocardiographic images.

J G Bosch1, L H Savalle, G van Burken, J H Reiber.   

Abstract

Quantitative analysis of echocardiographic sequences has been limited by time-consuming and strenuous manual tracing approaches. To circumvent these disadvantages, we have developed the EchoCardiographic Measurement System (ECHO-CMS). ECHO-CMS employs the robust, model-based Minimum Cost Contour Tracking technique for semiautomatic detection of left ventricular (LV) endocardial contours in sequences of consecutive echocardiographic images. An evaluation study was carried out on 20 short-axis patient studies (10 transesophageal and 10 transthoracic studies), each consisting of 16 consecutive images covering approximately one cardiac cycle. The LV endocardial contours in the 320 images were analyzed both by manual tracing and semiautomatically. In addition, interobserver and intraobserver variabilities were determined for both techniques in two patients (32 images). Manual editing was required in only 57 (18%) of all 320 contours detected. Average processing time per patient for manual tracing was 25 minutes (of which 18 1/2 minutes was for drawing and corrections) and for semiautomatic tracing it was only 5 1/2 minutes (of which just 1 1/2 minutes was for corrections). Regression analysis showed excellent correspondence between manual and semiautomatic tracing: semiautomatic = 1.01 manual + 5.58%; r = 0.989; standard error of the estimate = 11.9% (n = 320 contours). Interobserver and intraobserver variabilities were smaller for semiautomatic than for manual tracing, although not in all cases statistically significant. In conclusion, semiautomatic LV short-axis endocardial contour detection by ECHO-CMS provides contours that are highly similar to those drawn by an expert; it is five to 10 times faster than manual tracing and reduces intraobserver and interobserver variabilities. This demonstrates that ECHO-CMS is a useful tool for clinical echocardiographic research studies.

Entities:  

Mesh:

Year:  1995        PMID: 8611281     DOI: 10.1016/s0894-7317(05)80005-7

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  8 in total

1.  Lagrangian displacement tracking using a polar grid between endocardial and epicardial contours for cardiac strain imaging.

Authors:  Chi Ma; Tomy Varghese
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Myocardial viability: impact on left ventricular dilatation after acute myocardial infarction.

Authors:  F Nijland; O Kamp; P M J Verhorst; W G de Voogt; H G Bosch; C A Visser
Journal:  Heart       Date:  2002-01       Impact factor: 5.994

3.  Troponin T for the detection of dialysis-induced myocardial stunning in hemodialysis patients.

Authors:  Tobias Breidthardt; James O Burton; Aghogho Odudu; Mohamed Tarek Eldehni; Helen J Jefferies; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2012-07-19       Impact factor: 8.237

4.  Frequent hemodialysis schedules are associated with reduced levels of dialysis-induced cardiac injury (myocardial stunning).

Authors:  Helen J Jefferies; Bhupinder Virk; Brigitte Schiller; John Moran; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2011-05-19       Impact factor: 8.237

5.  Hemodialysis-induced cardiac injury: determinants and associated outcomes.

Authors:  James O Burton; Helen J Jefferies; Nicholas M Selby; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2009-04-08       Impact factor: 8.237

6.  Hemodialysis-induced cardiac dysfunction is associated with an acute reduction in global and segmental myocardial blood flow.

Authors:  Christopher W McIntyre; James O Burton; Nicholas M Selby; Lucia Leccisotti; Shvan Korsheed; Christopher S R Baker; Paolo G Camici
Journal:  Clin J Am Soc Nephrol       Date:  2007-11-14       Impact factor: 8.237

7.  Hemodialysis-induced repetitive myocardial injury results in global and segmental reduction in systolic cardiac function.

Authors:  James O Burton; Helen J Jefferies; Nicholas M Selby; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2009-10-01       Impact factor: 8.237

8.  Pediatric myocardial stunning underscores the cardiac toxicity of conventional hemodialysis treatments.

Authors:  Daljit K Hothi; Lesley Rees; Jan Marek; James Burton; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2009-04-01       Impact factor: 8.237

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.