Literature DB >> 8610727

Postprandial insulin profiles with implantable pump therapy may explain decreased frequency of severe hypoglycemia, compared with intensive subcutaneous regimens, in insulin-dependent diabetes mellitus patients.

D M Nathan1, F L Dunn, J Bruch, C McKitrick, M Larkin, C Haggan, J Lavin-Tompkins, D Norman, D Rogers, D Simon.   

Abstract

PURPOSE: To examine the mechanism of the decreased frequency of severe hypoglycemia with implantable pump therapy compared with subcutaneous intensive therapy. PATIENTS AND METHODS: Eight subjects with insulin-dependent diabetes mellitus (IDDM), enrolled in an implantable insulin pump study, were admitted to the General Clinical Research Center and on 2 separate days were given either a dose of preprandial insulin chosen to maintain normoglycemia for a standard (450 kcal, 50% carbohydrate) breakfast or 1.75 times the dose. The two doses were administered subcutaneously (by syringe or with an external pump) during one inpatient admission and by implantable pump (intraperitoneally, n=6; or intravenously, n=2) during a separate admission. Blood glucose, plasma-free insulin, and neurocognitive function were measured for 4 hours after the meal.
RESULTS: Subcutaneous administration resulted in 7 episodes of hypoglycemia (2 with the usual dose and 5 with the 1.75-fold dose), defined as blood glucose less than 50 mg/dL; implantable pump treatment resulted in only 2 episodes, both with the 1.75-fold dose (P <0.05, Fisher's two-tailed test for implantable versus subcutaneous). Compared with subcutaneous delivery, implantable pump therapy provided significantly lower insulin levels during the final 2 hours after administration of the usual dose and the 1.75-fold dose (P <0.005). In addition to the decreased frequency of hypoglycemia, implantable pump therapy resulted in significantly lower area under the glycemia curve during the first 120 minutes with the 1.75-fold dose compared with subcutaneous administration.
CONCLUSIONS: The lower frequency of severe hypoglycemia with intensive therapy administered by implantable pump therapy is explained by the more rapid clearance of insulin delivered intraperitoneally or intravenously compared with intensive subcutaneous injection regimens. The lower frequency of severe hypoglycemia with implantable pump therapy compared with subcutaneous therapy demonstrated in clinical trials is confirmed by this study, in which we attempted to induce hypoglycemia.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8610727     DOI: 10.1016/S0002-9343(97)89516-2

Source DB:  PubMed          Journal:  Am J Med        ISSN: 0002-9343            Impact factor:   4.965


  15 in total

Review 1.  Clinical pharmacokinetics during continuous ambulatory peritoneal dialysis.

Authors:  C A Taylor; E Abdel-Rahman; S W Zimmerman; C A Johnson
Journal:  Clin Pharmacokinet       Date:  1996-10       Impact factor: 6.447

2.  Intraperitoneal insulin delivery provides superior glycaemic regulation to subcutaneous insulin delivery in model predictive control-based fully-automated artificial pancreas in patients with type 1 diabetes: a pilot study.

Authors:  Eyal Dassau; Eric Renard; Jérôme Place; Anne Farret; Marie-José Pelletier; Justin Lee; Lauren M Huyett; Ankush Chakrabarty; Francis J Doyle; Howard C Zisser
Journal:  Diabetes Obes Metab       Date:  2017-07-06       Impact factor: 6.577

3.  A New Optimized Percutaneous Access System for CIPII.

Authors:  Rosa Garcia-Verdugo; Michael Erbach; Oliver Schnell
Journal:  J Diabetes Sci Technol       Date:  2017-03-01

4.  Realizing a Closed-Loop (Artificial Pancreas) System for the Treatment of Type 1 Diabetes.

Authors:  Rayhan A Lal; Laya Ekhlaspour; Korey Hood; Bruce Buckingham
Journal:  Endocr Rev       Date:  2019-12-01       Impact factor: 19.871

5.  Improved glycemic control with intraperitoneal versus subcutaneous insulin in type 1 diabetes: a randomized controlled trial.

Authors:  Susan J Logtenberg; Nanne Kleefstra; Sebastiaan T Houweling; Klaas H Groenier; Reinold O Gans; Evert van Ballegooie; Henk J Bilo
Journal:  Diabetes Care       Date:  2009-05-08       Impact factor: 17.152

6.  Insulin delivery route for the artificial pancreas: subcutaneous, intraperitoneal, or intravenous? Pros and cons.

Authors:  Eric Renard
Journal:  J Diabetes Sci Technol       Date:  2008-07

7.  Surgical aspects and complications of continuous intraperitoneal insulin infusion with an implantable pump.

Authors:  Jan Willem Haveman; Susan J J Logtenberg; Nanne Kleefstra; Klaas H Groenier; Henk J G Bilo; Adri M Blomme
Journal:  Langenbecks Arch Surg       Date:  2008-12-02       Impact factor: 3.445

Review 8.  Treating type 1 diabetes: from strategies for insulin delivery to dual hormonal control.

Authors:  A L McCall; L S Farhy
Journal:  Minerva Endocrinol       Date:  2013-06       Impact factor: 2.184

Review 9.  The challenges of achieving postprandial glucose control using closed-loop systems in patients with type 1 diabetes.

Authors:  Véronique Gingras; Nadine Taleb; Amélie Roy-Fleming; Laurent Legault; Rémi Rabasa-Lhoret
Journal:  Diabetes Obes Metab       Date:  2017-08-10       Impact factor: 6.577

Review 10.  Artificial pancreas: past, present, future.

Authors:  Claudio Cobelli; Eric Renard; Boris Kovatchev
Journal:  Diabetes       Date:  2011-11       Impact factor: 9.461

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.