Cuffed endotracheal tubes: mucosal pressures and tracheal wall blood flow.

P Dobrin, T Canfield.   

Abstract

Eighteen brands of cuffed endotracheal tubes, including those with the new low pressure cuffs, were evaluated and compared. Experiments were performed in vitro on excised dog tracheae to measure the mucosal pressure exerted by the inflated cuffs. Pressure was measured directly with a mechanical sensor. Latex cuffs exerted the highest mucosal pressures, whereas silicone cuffs exerted the lowest mucosal pressures. Polyvinyl chloride cuffs exerted intermediate levels of mucosal pressure. With each material, predistended cuffs exerted lower mucosal pressures than nonpredistended cuffs. A second set of experiments was performed in vivo to determine the effect of mucosal pressure on tracheal wall blood flow. These studies employed a thermistor technic. The data showed that, when inflated sufficiently to seal within the trachea, stiff cuffs reduced blood flow more than compliant cuffs. With all cuffs, blood flow was reduced more at the mucosa than at deeper regions of the tracheal wall.It was concluded that for clinical use, compliant cuffs are preferable to stiff cuffs because they should cause less ischemia.

Entities:  

Mesh:

Year:  1977        PMID: 860779     DOI: 10.1016/0002-9610(77)90008-3

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  11 in total

1.  Morphologic study of the adult trachea at the 7th and 12th ring. A study on specimens from 205 autopsies.

Authors:  G A Baer; M Terho; T Tiensuu
Journal:  Surg Radiol Anat       Date:  1987       Impact factor: 1.246

2.  Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs.

Authors:  R D Seegobin; G L van Hasselt
Journal:  Br Med J (Clin Res Ed)       Date:  1984-03-31

3.  Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial.

Authors:  Ji-Hoon Park; Hyo-Jin Lee; Sou Hyun Lee; Ji Seob Kim
Journal:  Medicine (Baltimore)       Date:  2021-07-23       Impact factor: 1.817

4.  Vocal cord paralysis associated with difficult gastric tube insertion.

Authors:  T Ibuki; N Ando; Y Tanaka
Journal:  Can J Anaesth       Date:  1994-05       Impact factor: 5.063

5.  The pressure exerted on the tracheal wall by two endotracheal tube cuffs: A prospective observational bench-top, clinical and radiological study.

Authors:  Alex Doyle; Ramai Santhirapala; Martin Crowe; Mark Blunt; Peter Young
Journal:  BMC Anesthesiol       Date:  2010-12-09       Impact factor: 2.217

6.  The changes of endotracheal tube cuff pressure by the position changes from supine to prone and the flexion and extension of head.

Authors:  Deokkyu Kim; Byeongdo Jeon; Ji-Seon Son; Jun-Rae Lee; Seonghoon Ko; Hyungsun Lim
Journal:  Korean J Anesthesiol       Date:  2015-01-28

7.  Allomyrina Dichotoma Larvae Regulate Food Intake and Body Weight in High Fat Diet-Induced Obese Mice Through mTOR and Mapk Signaling Pathways.

Authors:  Jongwan Kim; Eun-Young Yun; Seong-Won Park; Tae-Won Goo; Minchul Seo
Journal:  Nutrients       Date:  2016-02-18       Impact factor: 5.717

8.  Comparison of the cuff pressure of a TaperGuard endotracheal tube and a cylindrical endotracheal tube after lateral rotation of head during middle ear surgery: A single-blind, randomized clinical consort study.

Authors:  Eunkyung Choi; Yongmin Park; Younghoon Jeon
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

9.  Comparison of Pressure Changes by Head and Neck Position between High-Volume Low-Pressure and Taper-Shaped Cuffs: A Randomized Controlled Trial.

Authors:  Nobuyasu Komasawa; Ryosuke Mihara; Kentaro Imagawa; Kazuo Hattori; Toshiaki Minami
Journal:  Biomed Res Int       Date:  2015-10-05       Impact factor: 3.411

10.  Assessing the accuracy of ultrasound measurements of tracheal diameter: an in vitro experimental study.

Authors:  Ran Ye; Feifei Cai; Chengnan Guo; Xiaocheng Zhang; Dan Yan; Chengshui Chen; Bin Chen
Journal:  BMC Anesthesiol       Date:  2021-06-24       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.