Literature DB >> 8600965

Influence of a non-ionic radiography contrast medium on the microcirculation.

R Bach1, F Jung, B Scheller, B Hummel, C Ozbek, S Spitzer, H Schieffer.   

Abstract

UNLABELLED: PURPOSE,
MATERIAL AND METHODS: Microcirculatory disturbances may be responsible for some of the adverse effects induced by contrast media. The influence of iopromide 370 (Ultravist) on cutaneous microcirculation was therefore investigated in 15 patients in a prospective study. Twenty ml of iopromide and 20 ml 0.9% NaCl were injected as reference in the subclavian artery at the beginning of a diagnostic coronary angiography. Erythrocyte velocity was measured in ipsilateral nailfold capillaries at the beginning of, during, and after the injection continuously up to 6 min after injection.
RESULTS: On average, 30 s after injection of contrast medium, erythrocyte velocity decreased significantly by 51.3% (p<0.0001) and remained reduced up to 120 s. This reaction was observed in 14 out of 15 patients. Three patients showed a temporary cessation of capillary blood flow.
CONCLUSION: The adverse effects sometimes seen during coronary angiography can be explained if similar contrast medium induced microcirculatory disturbances in the myocardial vasculature.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8600965     DOI: 10.1177/02841851960371P144

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  4 in total

Review 1.  [Optimal x-ray contrast media for ambulatory coronary angiography from the microcirculatory point of view].

Authors:  R Bach; F Jung
Journal:  Herz       Date:  1998-02       Impact factor: 1.443

2.  Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS).

Authors:  Philipp Lamby; Friedrich Jung; Stefanie Graf; Lotte Schellenberg; Johannes Falter; Natascha Platz-da-Silva; Stephan Schreml; Lukas Prantl; Ralf P Franke; Ernst M Jung
Journal:  Sci Rep       Date:  2017-10-13       Impact factor: 4.379

3.  Effect of radiographic contrast media on the spectrin/band3-network of the membrane skeleton of erythrocytes.

Authors:  Ralf-Peter Franke; Tim Scharnweber; Rosemarie Fuhrmann; Folker Wenzel; Anne Krüger; Christof Mrowietz; Friedrich Jung
Journal:  PLoS One       Date:  2014-02-24       Impact factor: 3.240

Review 4.  Effects of radiographic contrast media on the micromorphology of the junctional complex of erythrocytes visualized by immunocytology.

Authors:  Ralf-Peter Franke; Anne Krüger; Tim Scharnweber; Folker Wenzel; Friedrich Jung
Journal:  Int J Mol Sci       Date:  2014-09-12       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.