Literature DB >> 8594064

Noninvasive quantification of rCBF using positron emission tomography.

H Watabe1, M Itoh, V Cunningham, A A Lammertsma, P Bloomfield, M Mejia, T Fujiwara, A K Jones, T Jones, T Nakamura.   

Abstract

This study proposes a new method for the pixel-by-pixel quantification of regional CBF (rCBF) with positron emission tomography and H(15)(2)O by using a reference tissue region. No arterial blood is required. Simulation studies revealed that the calculation of rCBF was fairly stable provided that the frame time was relatively short compared with total scan time. In practice, calculated CBF images correlated significantly with those obtained with the dynamic/integral method. Because the method accurately detects changes in CBF, it is particularly suitable for brain activation studies.

Entities:  

Mesh:

Year:  1996        PMID: 8594064     DOI: 10.1097/00004647-199603000-00017

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  7 in total

1.  Kinetics modeling and occupancy studies of a novel C-11 PET tracer for VAChT in nonhuman primates.

Authors:  Hongjun Jin; Xiang Zhang; Xuyi Yue; Hui Liu; Junfeng Li; Hao Yang; Hubert Flores; Yi Su; Stanley M Parsons; Joel S Perlmutter; Zhude Tu
Journal:  Nucl Med Biol       Date:  2015-11-07       Impact factor: 2.408

2.  A positron-probe system for arterial input function quantification for positron emission tomography in humans.

Authors:  Kihak Lee; Peter T Fox; Jack L Lancaster; Paul A Jerabek
Journal:  Rev Sci Instrum       Date:  2008-06       Impact factor: 1.523

3.  In Vivo Characterization of Two 18F-Labeled PDE10A PET Radioligands in Nonhuman Primate Brains.

Authors:  Hui Liu; Hongjun Jin; Zonghua Luo; Xuyi Yue; Xiang Zhang; Hubert Flores; Yi Su; Joel S Perlmutter; Zhude Tu
Journal:  ACS Chem Neurosci       Date:  2018-02-19       Impact factor: 4.418

4.  Preclinical evaluation of a promising C-11 labeled PET tracer for imaging phosphodiesterase 10A in the brain of living subject.

Authors:  Hui Liu; Hongjun Jin; Xuyi Yue; Xiang Zhang; Hao Yang; Junfeng Li; Hubert Flores; Yi Su; Joel S Perlmutter; Zhude Tu
Journal:  Neuroimage       Date:  2015-07-26       Impact factor: 6.556

5.  Quantitative cerebral H2(15)O perfusion PET without arterial blood sampling, a method based on washout rate.

Authors:  Valerie Treyer; Mathieu Jobin; Cyrill Burger; Vincenzo Teneggi; Alfred Buck
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-01-28       Impact factor: 9.236

6.  Comparison of [11C]TZ1964B and [18F]MNI659 for PET imaging brain PDE10A in nonhuman primates.

Authors:  Hui Liu; Hongjun Jin; Xuyi Yue; Junbin Han; Hao Yang; Hubert Flores; Yi Su; David Alagille; Joel S Perlmutter; Gilles Tamagnan; Zhude Tu
Journal:  Pharmacol Res Perspect       Date:  2016-08-26

7.  Semi-quantitative cerebral blood flow parameters derived from non-invasive [15O]H2O PET studies.

Authors:  Thomas Koopman; Maqsood Yaqub; Dennis Fr Heijtel; Aart J Nederveen; Bart Nm van Berckel; Adriaan A Lammertsma; Ronald Boellaard
Journal:  J Cereb Blood Flow Metab       Date:  2017-09-13       Impact factor: 6.200

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.