Literature DB >> 8588966

Internal fixation of the distal radius. A comparative, experimental study.

C P Rader1, C Räuber, K E Rehm, J Koebke.   

Abstract

In a comparative, experimental examination of 60 human cadaver radii, the stability of various, widely used internal fixation procedures of a distal radius fracture loco typico using a dorsal wedge was determined. The use of 2.5-mm Kirschner wires (K-wires) delivered a 10% greater stability than 1.8-mm K-wires. The 2.7-mm polylactide rods achieved a slightly greater stability than 1.8-mm K-wires under accurate pinning conditions. Polylactide rods (35 mm length, 2 mm diameter) and polyglycolide rods (60 mm length, 2 mm diameter) proved to be 20% less solid than 1.8-mm K-wires and almost 45% less than plate fixation. The short polylactide pins, however, did not have enough hold in the proximal cortical bone. The 2.7-mm polylactide rods (60 mm length) complied with the stability prerequisites necessary for comparable substitution for K-wires in distal radius fractures.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8588966     DOI: 10.1007/bf00448958

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  11 in total

1.  [Operative treatment of certain cases of distal radius fracture].

Authors:  H WILLENEGGER; A GUGGENBUHL
Journal:  Helv Chir Acta       Date:  1959-06

2.  [The density of cortical bone of the distal radius].

Authors:  J Mockenhaupt
Journal:  Unfallchirurgie       Date:  1990-08

3.  Intramedullary fixation of cortical bone osteotomies with self-reinforced polylactic rods in rabbits.

Authors:  A Majola; S Vainionpää; K Vihtonen; J Vasenius; P Törmälä; P Rokkanen
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

4.  [Choice of surgical procedure of the distal radius. Bore wire versus plate].

Authors:  R Letsch; K P Schmit-Neuerburg; M Schax
Journal:  Aktuelle Traumatol       Date:  1987-06

5.  [Surgical treatment of distal radius fracture with external fixation].

Authors:  H E Wagner; R P Jakob
Journal:  Unfallchirurg       Date:  1985-11       Impact factor: 1.000

Review 6.  [Current status of the treatment of distal radius fracture].

Authors:  H Tscherne; J Jähne
Journal:  Unfallchirurg       Date:  1990-04       Impact factor: 1.000

7.  [Distal radius fracture. Fracture stabilization with biodegradable osteosynthesis pins (Biofix). Experimental studies and initial clinical experiences].

Authors:  R Hoffmann; C Krettek; N Haas; H Tscherne
Journal:  Unfallchirurg       Date:  1989-09       Impact factor: 1.000

8.  Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial.

Authors:  P P Casteleyn; F Handelberg; P Haentjens
Journal:  J Bone Joint Surg Br       Date:  1992-11

9.  [Osteosynthesis of distal radius fractures with biodegradable fracture rods. Results of two years follow-up].

Authors:  R Hoffmann; C Krettek; A Hetkämper; N Haas; H Tscherne
Journal:  Unfallchirurg       Date:  1992-02       Impact factor: 1.000

10.  [Percutaneous drill wire fixation in treating distal radius fractures at risk of dislocation].

Authors:  O Kwasny; H Hertz; R Schabus
Journal:  Aktuelle Traumatol       Date:  1990-04
View more
  1 in total

1.  [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

Authors:  M Hakimi; P Jungbluth; S Gehrmann; J Nowak; J Windolf; M Wild
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.