Literature DB >> 8587001

Evaluation of a dipstick method for the detection of human immunodeficiency virus infection.

C N Beristain1, L F Rojkin, L E Lorenzo.   

Abstract

Serology has been a fundamental tool to prevent post-transfusional infection with human immunodeficiency virus (HIV) and for epidemiological surveys, the first step to attempt control of the pandemia. Enzyme immunoassay is in widespread use. Nevertheless, simpler methods are needed in many countries, where laboratory facilities and trained personnel are limited, and HIV prevalence is high. The evaluation of a simple and noninstrumented HIV antibody test is presented here. The test employs synthetic antigens of HIV-1 and HIV-2 attached to the teeth of a polystyrene comb, which fit into the wells of standard microtiter plates where samples are diluted. Captured antibodies are developed with colloidal gold-labeled Protein A. Three seroconversion panels plus 662 samples were tested, including HIV-1 and HIV-2-infected individuals, normal blood donors, and a noninfected baby born to a seroreactive mother. When compared with enzyme-linked immunosorbent assay (ELISA) and Western blot, the dipstick showed 100% sensitivity and 98.7% specificity. The simplicity of result evaluations and excellent reagent stability make the dipstick suitable for small blood banks and for epidemiological surveys.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8587001     DOI: 10.1002/jcla.1860090603

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  3 in total

1.  Evaluation of dot immunogold filtration assay for anti-HAV IgM antibody.

Authors:  Wei Wu; De-Zhong Xu; Yong-Ping Yan; Jing-Xia Zhang; Ying Liu; Ru-Lin Li
Journal:  World J Gastroenterol       Date:  1999-04       Impact factor: 5.742

2.  Evaluation of Dot Immunogold Filtration Assay (DIGFA) By Recombinant Protein EPC1 for Anti- Echinococcus granulosus IgG Antibody.

Authors:  Somayeh Kordafshari; Seyed Hossein Hosseini; Fatemeh Jalousian; Masoumeh Rajabibazl; Malcolm Jones; Fazeleh Etebar
Journal:  Iran J Parasitol       Date:  2015 Jan-Mar       Impact factor: 1.012

3.  Rapid and simple detection of Tamiflu-resistant influenza virus: Development of oseltamivir derivative-based lateral flow biosensor for point-of-care (POC) diagnostics.

Authors:  Seul Gee Hwang; Kab Ha; Kyeonghye Guk; Do Kyung Lee; Gayoung Eom; Sinae Song; Taejoon Kang; Hwangseo Park; Juyeon Jung; Eun-Kyung Lim
Journal:  Sci Rep       Date:  2018-08-29       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.