Literature DB >> 8582915

Mechanical and histological investigation of hydrothermally treated and untreated anodic titanium oxide films containing Ca and P.

H Ishizawa1, M Fujino, M Ogino.   

Abstract

In a previous study a new method for forming thin hydroxyapatite (HA) layers on titanium was described. Titanium was anodized at 350 V in an electrolyte solution containing sodium beta-glycerophosphate and calcium acetate, and an anodic titanium oxide film containing Ca and P (AOFCP) was formed on the surface. Then numerous HA crystals were precipitated on the AOFCP during hydrothermal treatment in high-pressure steam at 300 degrees C. In this study three types of hydrothermally treated films differing in amounts of precipitated HA crystals and tensile adhesive strength, and untreated films were histologically and mechanically investigated in a transcortical rabbit femoral model for 8 weeks of implantation using light microscopy, scanning electron microscopy (SEM), and push-out tests. Machined titanium and HA ceramics served as control materials. The push-out shear strength and bone apposition of the AOFCP significantly increased after hydrothermal treatment, and were equivalent to those of HA ceramics, although the HA layer on the AOFCP was thin at 1-2 microns. From SEM observation of the pushed-out specimen, it was found that the thin HA layer had directly bonded to bone but the AOFCP had not. The push-out strength of the hydrothermally treated film resulted from the chemical bonding of the bone-HA layer interface, while that of the untreated film resulted from mechanical interlocking force between bone and the microprojections. There was a small difference in bone apposition but no significant difference in push-out strength with the amount of precipitated HA crystals on the treated films. Among the treated films, the film formed at the lowest electrolyte concentration showed the lowest bone apposition because of incomplete covering by the HA crystals, and showed the highest stability against mechanical failure because the adhesive strength was very high at about 38 mPa. Also, the hydrothermally untreated anodic oxide films, whose surfaces were rough as a result of the large microprojections, showed much higher push-out strength and bone apposition than titanium. The good hard-tissue compatibility may be attributed to the surface roughness and the possible inhibition of titanium ion release from the specimen.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8582915     DOI: 10.1002/jbm.820291118

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  10 in total

1.  In vitro biocompatibility of orthodontic miniscrews with human gingival fibroblast and SAOS-2 osteoblast cultures.

Authors:  Hannah Finke; Bernd Koos; Helge Fischer-Brandies; Martha Es-Souni
Journal:  J Orofac Orthop       Date:  2018-07-16       Impact factor: 1.938

2.  Characterization of surface oxide films on titanium and bioactivity.

Authors:  B Feng; J Y Chen; S K Qi; L He; J Z Zhao; X D Zhang
Journal:  J Mater Sci Mater Med       Date:  2002-05       Impact factor: 3.896

Review 3.  Dental implant systems.

Authors:  Yoshiki Oshida; Elif B Tuna; Oya Aktören; Koray Gençay
Journal:  Int J Mol Sci       Date:  2010-04-12       Impact factor: 5.923

Review 4.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

5.  Nanoscale Surface Modifications of Orthopaedic Implants: State of the Art and Perspectives.

Authors:  Rmt Staruch; M F Griffin; Pem Butler
Journal:  Open Orthop J       Date:  2016-12-30

6.  Cathodic Polarization Coats Titanium Based Implant Materials with Enamel Matrix Derivate (EMD).

Authors:  Matthias J Frank; Martin S Walter; Marina Rubert; Bernd Thiede; Marta Monjo; Janne E Reseland; Håvard J Haugen; Ståle Petter Lyngstadaas
Journal:  Materials (Basel)       Date:  2014-03-14       Impact factor: 3.623

7.  In Vitro and In Vivo Biocompatibility Studies of a Cast and Coated Titanium Alloy.

Authors:  Ursula Sommer; Stephan Laurich; Lucie de Azevedo; Katharina Viehoff; Sabine Wenisch; Ulrich Thormann; Volker Alt; Christian Heiss; Reinhard Schnettler
Journal:  Molecules       Date:  2020-07-27       Impact factor: 4.411

Review 8.  A Review of Anodized TiNbSn Alloys for Improvement in Layer Quality and Application to Orthopedic Implants.

Authors:  Yu Mori; Naoya Masahashi; Toshimi Aizawa
Journal:  Materials (Basel)       Date:  2022-07-22       Impact factor: 3.748

9.  In vitro Evaluation of Calcium Phosphate Precipitation on Possibly Bioactive Titanium Surfaces in the Presence of Laminin.

Authors:  Kostas Bougas; Victoria Franke Stenport; Fredrik Currie; Ann Wennerberg
Journal:  J Oral Maxillofac Res       Date:  2011-10-01

10.  Laminin Coating Promotes Calcium Phosphate Precipitation on Titanium Discs in vitro.

Authors:  Kostas Bougas; Victoria Franke Stenport; Fredrik Currie; Ann Wennerberg
Journal:  J Oral Maxillofac Res       Date:  2012-01-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.