| Literature DB >> 858225 |
Abstract
The XAD-2 resin extraction procedure is rapidly becoming an important tool for both the clinical and forensic toxicology laboratory. Although different investigators use different elution solvents and techniques, the basic procedure is to adsorb drugs onto the XAD-2 resin and then elute these drugs with an appropriate organic solvent. A number of parameters have been shown to be involved in obtaining good results. These include pH of sample, flow rate, type and volume of eluting solvent. These parameters can be adjusted so that maximum overall drug recoveries are obtained. Since XAD-2 extraction of urine by Fujimoto and Wang [2] was introduced, the procedure has been extended to all types of biologic specimens. Various elution techniques have been reported [12, 13], namely, the differential elution of drugs from the resin into acid and neutral, and basic drug fractions. Overall, the techniques vary from rapid simple procedures for drugs of abuse in urine to more elaborate methods of extraction of autopsy material. The extraction procedure itself is flexible enough so as to suit the needs of almost any toxicology laboratory.Mesh:
Substances:
Year: 1977 PMID: 858225 DOI: 10.3109/15563657708987959
Source DB: PubMed Journal: Clin Toxicol ISSN: 0009-9309 Impact factor: 4.467