Literature DB >> 8574529

Composite porosity of expanded polytetrafluoroethylene vascular prosthesis.

T Nagae1, H Tsuchida, S K Peng, K Furukawa, S E Wilson.   

Abstract

Polytetrafluoroethylene (PTFE) prostheses were modified to produce two types of composite porosity PTFE grafts: type I--inner 60 microns/outer 20 microns and type II--inner 20 microns/outer 60 microns. These composite porosity PTFE designs were investigated for bleed through, graft healing and patency and compared with high porosity PTFE (60 microns) and standard PTFE (20 microns) grafts. The grafts were implanted into the carotid and femoral arteries of dogs and retrieved after 4, 12 and 18 weeks. Both composite porosity grafts showed significantly less bleed through than standard and high porosity grafts after reperfusion. In composite grafts, the 60-microns layer allowed fibrovascular tissue and histiocyte ingrowth from perigraft tissue, but the 20-microns layer did not. Neointima formation occurred earlier and endothelialization was more extensive in high porosity grafts, but seroma formation occurred in 25% of cases. In type I composite porosity grafts, smooth muscle cells of neointima migrated into the pores of the graft, providing a firmly anchored intima. Type II composite porosity grafts allowed better ingrowth of fibrovascular tissue at the outer layer from the perigraft tissue; however, endothelialization was not completed. Composite porosity grafts should be considered for evaluation in specific clinical situations.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8574529     DOI: 10.1016/0967-2109(95)94445-3

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  3 in total

1.  Early mediastinal seroma secondary to modified Blalock-Taussig shunts--successful management by percutaneous drainage.

Authors:  Bairbre L Connolly; Michael J Temple; Peter G Chait; Ricardo Restrepo; Ian Adatia
Journal:  Pediatr Radiol       Date:  2003-03-28

2.  Accelerated neovascularization and endothelialization of vascular grafts promoted by covalently bound laminin type 1.

Authors:  Stuart K Williams; Leigh B Kleinert; Vangie Patula-Steinbrenner
Journal:  J Biomed Mater Res A       Date:  2011-07-28       Impact factor: 4.396

3.  The Influence of a Knitted Hydrophilic Prosthesis of Blood Vessels on the Activation of Coagulation System-In Vitro Study.

Authors:  Maria Szymonowicz; Maciej Dobrzynski; Sara Targonska; Agnieszka Rusak; Zbigniew Rybak; Marcin H Struszczyk; Jacek Majda; Damian Szymanski; Rafal J Wiglusz
Journal:  Nanomaterials (Basel)       Date:  2021-06-18       Impact factor: 5.076

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.