Literature DB >> 8573907

Hemodialysis access recirculation measured by ultrasound dilution.

T A Depner1, N M Krivitski, D MacGibbon.   

Abstract

The most widely used clinical method for measuring recirculation in the access device is based on urea dilution. The three simultaneous blood samples required during hemodialysis interrupt the treatment, and results of chemical analysis are often delayed for several days. Alternatively, detecting recirculation by dilution of arterial blood caused by a bolus of normal saline injected into the venous blood line has several advantages. In this study, an ultrasound sensor clamped onto the arterial line entering the dialyzer was used to detect such dilution from a reduction in sound velocity observed in the saline diluted blood. Within the target range, the change in ultrasound velocity (ultrasound dilution) is linearly correlated with the dilution of whole blood by normal saline. The same sensor was also used to measure flow in the blood line using an established ultrasound transit-time method. During 34 hemodialyses in 28 patients, only 3 patients had detectable recirculation measured by ultrasound dilution. To further evaluate the sensitivity of the new method the dialysis lines were reversed during hemodialysis in the 25 patients with no recirculation. After this, all had detectable recirculation ranging from 10 to 60%. The mean error of duplicate measurements was 3.9 +/- 2.8%. Recirculation by ultrasound dilution correlated closely with recirculation measured by urea dilution (r = 0.9156, p < 001). The data suggest that the ultrasound dilution method is both sensitive and accurate. Ease of use and immediate availability of results added to the clinical usefulness of this method for evaluating the integrity of the hemodialysis access.

Entities:  

Mesh:

Year:  1995        PMID: 8573907     DOI: 10.1097/00002480-199507000-00113

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  Lymph flow pattern in the intact thoracic duct in sheep.

Authors:  M Onizuka; T Flatebø; G Nicolaysen
Journal:  J Physiol       Date:  1997-08-15       Impact factor: 5.182

2.  Surveillance of hemodialysis vascular access.

Authors:  William L Whittier
Journal:  Semin Intervent Radiol       Date:  2009-06       Impact factor: 1.513

Review 3.  Vascular access for hemodialysis: postoperative evaluation and function monitoring.

Authors:  Konstantinos Leivaditis; Stelios Panagoutsos; Athanasios Roumeliotis; Vassilios Liakopoulos; Vassilis Vargemezis
Journal:  Int Urol Nephrol       Date:  2013-09-18       Impact factor: 2.370

4.  Catheter Port Reversal in Citrate Continuous Veno-Venous Hemofiltration.

Authors:  Willem Boer; Mathias Van Tornout; Margot Vander Laenen; Kim Engelen; Ingrid Meex; Philippe Jorens
Journal:  Kidney Int Rep       Date:  2021-08-13

5.  Development and Validation of a Machine Learning Model Predicting Arteriovenous Fistula Failure in a Large Network of Dialysis Clinics.

Authors:  Ricardo Peralta; Mario Garbelli; Francesco Bellocchio; Pedro Ponce; Stefano Stuard; Maddalena Lodigiani; João Fazendeiro Matos; Raquel Ribeiro; Milind Nikam; Max Botler; Erik Schumacher; Diego Brancaccio; Luca Neri
Journal:  Int J Environ Res Public Health       Date:  2021-11-24       Impact factor: 3.390

6.  A review article: access recirculation among end stage renal disease patients undergoing maintenance hemodialysis.

Authors:  Abbasali Zeraati; Seyed Seifollah Beladi Mousavi; Marzieh Beladi Mousavi
Journal:  Nephrourol Mon       Date:  2013-03-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.