Literature DB >> 857264

Measurements of the microscopic structure of cortical bone.

A H Beddoe.   

Abstract

A technique is described in which the microstructure of cortical bone is analysed in terms of distributions of possible paths which ionizing particles take as they transverse the soft-tissue cavities and mineralized component. Measurements are restricted to transverse planes in the long bones, but a method is suggested for generating approximate omnidirectional path-length distributions from the measured transverse distributions. Results are presented for some long bones of a 50 year old man, a 9 year old boy and a young adult beagle, and these suggest that considerable structural differences occur between the two species. Values of some commonly quoted structural parameters are also given. For example, mean transverse cavity path lengths range between 67 and 99 micron in the long bones of the adult man compared with 29 micron in the beagle femur; the corresponding mean path lengths through the mineralized component are 830-1040 and 1500 micron. Finally, the total cavity plus periosteal surface for cortical bone in adult man is estimated to be about 6 m2.

Entities:  

Mesh:

Year:  1977        PMID: 857264     DOI: 10.1088/0031-9155/22/2/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry.

Authors:  Cecilia Hindorf; Gerhard Glatting; Carlo Chiesa; Ola Lindén; Glenn Flux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06       Impact factor: 9.236

2.  Three-dimensional reconstruction of Haversian systems in human cortical bone using synchrotron radiation-based micro-CT: morphology and quantification of branching and transverse connections across age.

Authors:  Isabel S Maggiano; Corey M Maggiano; John G Clement; C David L Thomas; Yasmin Carter; David M L Cooper
Journal:  J Anat       Date:  2016-01-07       Impact factor: 2.610

3.  A quantitative study of the structure of trabecular bone in man, rhesus monkey, beagle and miniature pig.

Authors:  A H Beddoe
Journal:  Calcif Tissue Res       Date:  1978-08-18

4.  Magnetic resonance imaging assessed cortical porosity is highly correlated with μCT porosity.

Authors:  Won C Bae; Shantanu Patil; Reni Biswas; Shihong Li; Eric Y Chang; Sheronda Statum; Darryl D D'Lima; Christine B Chung; Jiang Du
Journal:  Bone       Date:  2014-06-11       Impact factor: 4.398

5.  Radiopharmaceutical therapy of bone metastases with 89SrCl2, 186Re-HEDP and 153Sm-EDTMP: a dosimetric study using Monte Carlo simulation.

Authors:  L Strigari; R Sciuto; M D'Andrea; R Pasqualoni; M Benassi; C L Maini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-20       Impact factor: 10.057

Review 6.  A physiologically based kinetic model for lead in children and adults.

Authors:  E J O'Flaherty
Journal:  Environ Health Perspect       Date:  1998-12       Impact factor: 9.031

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.