Evaluation of a fully automated end-tidal carbon monoxide instrument for breath analysis.

H J Vreman1, L M Baxter, R T Stone, D K Stevenson.   

Abstract

We evaluated a novel, portable breath sampler/CO-quantifying instrument [Baby's Breath Carbon Monoxide Analyzer (BB); Natus Medical], developed for use at the bedside or with gas samples collected into bags. Bench tests demonstrated that the CO measurements were linear, accurate, and precise when compared with gas chromatography (GC) results. In vivo tests (n = 30) performed with adults showed excellent correlation between end-tidal breath CO measurements (ETCO) corrected for inhaled CO (ETCOc) as determined by BB and GC. Breath sampling efficiency was 96%. ETCOc measurements and blood carboxyhemoglobin fractions (% of total hemoglobin) corrected for inhaled CO (COHbc) correlated strongly: COHbc = 0.25 ETCOc--0.01 microL/L CO (r2 = 0.97, Sy/x = 0.47, SE slope = 0.01, n = 30). The imprecision, assessed by the mean of the population's CV for triplicate determinations, was 11%. Measurements with healthy and hemolytic term newborns showed that ETCOc values of > 3 microL/L correlated with known hemolytic conditions. We conclude that this instrument is clinically reliable and can be used to noninvasively measure ETCO in neonates and adults.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8565232

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

Review 1.  New technologies in the use of exhaled breath analysis for biological monitoring.

Authors:  H K Wilson; A C Monster
Journal:  Occup Environ Med       Date:  1999-11       Impact factor: 4.402

2.  Validation of the Natus CO-Stat End Tidal Breath Analyzer in children and adults.

Authors:  H J Vreman; R J Wong; P Harmatz; A A Fanaroff; B Berman; D K Stevenson
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

Review 3.  Carbon monoxide in exhaled breath testing and therapeutics.

Authors:  Stefan W Ryter; Augustine M K Choi
Journal:  J Breath Res       Date:  2013-02-27       Impact factor: 3.262

Review 4.  End-tidal carbon monoxide and hemolysis.

Authors:  G F Tidmarsh; R J Wong; D K Stevenson
Journal:  J Perinatol       Date:  2014-04-17       Impact factor: 2.521

5.  Reliable Breathing Tracking with Wearable Mask Device.

Authors:  Vishal Varan Tipparaju; Xiaojun Xian; Devon Bridgeman; Di Wang; Francis Tsow; Erica Forzani; Nongjian Tao
Journal:  IEEE Sens J       Date:  2020-02-27       Impact factor: 3.301

6.  Metalloporphyrins - an update.

Authors:  Stephanie Schulz; Ronald J Wong; Hendrik J Vreman; David K Stevenson
Journal:  Front Pharmacol       Date:  2012-04-26       Impact factor: 5.810

7.  Correlation of exhaled carbon monoxide level with disease severity in chronic obstruction pulmonary disease.

Authors:  Md Arshad Ejazi; Mohammad Shameem; Rakesh Bhargava; Zuber Ahmad; Jamal Akhtar; Nafeees A Khan; Md Mazhar Alam; Md Arif Alam; C G Adil Wafi
Journal:  Lung India       Date:  2018 Sep-Oct
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.