The time-variable photoplethysmographic signal; dependence of the heart synchronous signal on wavelength and sample volume.

H Ugnell1, P A Oberg.   

Abstract

The photoplethysmorgraphic signal (PPG) from forearm skin and the ECG were recorded simultaneously from healthy subjects. The optical signal was derived with a fibre-optic probe which consisted of 61 fibre pairs. The peak-to-peak averaged a.c.-signal was calculated. The dependency of this signal and the signal-to-noise ratio (SNR) on the light wavelength and on sample volume was studied. The light intensities used at 560 nm were 0.015 and 0.029 mWmm-2 and at 940 nm we used 0.029, 1.37 and 2.77 mWmm-2. A theoretical model for calculation of the sample volumes was also developed. The amplitude and SNR of the a.c.-signal at 560 nm is larger than at 940 nm at the same intensity (0.029 mWmm-2). At 940 nm using 1.37 and 2.77 mWmm-2 the a.c.-signal increased with the number of fibre pairs (volume) while the SNR was little affected. At 560 nm it is suggested that the major contribution to the a.c.-signal is pulsations in the ascending arterioles and at 940 nm from pulsations in the larger vessels deeper in the tissue volume under study.

Mesh:

Year:  1995        PMID: 8564151     DOI: 10.1016/1350-4533(95)00008-b

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Multilaser photoplethysmography technique.

Authors:  L Gailite; J Spigulis; A Lihachev
Journal:  Lasers Med Sci       Date:  2007-07-14       Impact factor: 3.161

2.  Optical assessment of recovery of tissue blood supply after removal of externally applied pressure.

Authors:  A Murray; D Marjanovic
Journal:  Med Biol Eng Comput       Date:  1997-07       Impact factor: 2.602

Review 3.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

4.  iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

Authors:  Kenta Matsumura; Peter Rolfe; Jihyoung Lee; Takehiro Yamakoshi
Journal:  PLoS One       Date:  2014-03-11       Impact factor: 3.240

5.  Imaging PPG for In Vivo Human Tissue Perfusion Assessment during Surgery.

Authors:  Marco Lai; Stefan D van der Stel; Harald C Groen; Mark van Gastel; Koert F D Kuhlmann; Theo J M Ruers; Benno H W Hendriks
Journal:  J Imaging       Date:  2022-03-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.