Literature DB >> 8563154

Anatomic considerations for dorsal sacral plate-screw fixation.

R Xu1, N A Ebraheim, A Mohamed, H el-Gamal, R A Yeasting.   

Abstract

Five cadaveric pelves and 40 dry bony specimens were used to assess the feasibility of the lumbosacral plate fixation extending to beyond the S1 region and quantitatively to evaluate the posterior sacroiliac region and the dimensions of S1 and S2 pedicle and lateral mass. Partial removal of the posterior ilium was undertaken to measure the surface area available for plate fixation on the dorsal aspect of the sacrum. The results showed that the average distances between the outer edges of S1 and S2 dorsal foramina and the medial edge of the posterior ilium increased from 11.3 mm before removal of a portion of the medial posterior ilium to 16.6 mm after removal at the S1 level, and from 8.4 mm before removal of partial medial posterior ilium to 13 mm after removal at the S2 level, respectively. The average depths of the S1 and S2 pedicles were 37.1 and 32.2 mm in the direction anteromedial to the sagittal plane, respectively. The average depths of the S1 and S2 lateral mass were 37.3 and 33.9 mm in the direction anterolateral to the sagittal plane, respectively. In cases of vertebral metastases or osteoporosis, plating extending to S2 may be needed if good bony purchase cannot be achieved by the S1 pedicle or lateral mass screw. This study suggested also that partial removal of the posterior ilium enhances the space on the posterior aspect of the sacrum without severe compromise of the sacroiliac joint.

Entities:  

Mesh:

Year:  1995        PMID: 8563154

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  5 in total

1.  A study of sacral anthropometry to determine S1 screw placement for spinal lumbosacral fixation in the Korean population.

Authors:  Young-Yul Kim; Kee-Yong Ha; Sang-Il Kim; In-Soo Oh
Journal:  Eur Spine J       Date:  2015-07-31       Impact factor: 3.134

2.  L5 spinal nerve injury caused by misplacement of outwardly-inserted S1 pedicle screws.

Authors:  Masahiro Inoue; Gen Inoue; Tomoyuki Ozawa; Masayuki Miyagi; Hiroto Kamoda; Tetsuhiro Ishikawa; Miyako Suzuki; Yoshihiro Sakuma; Yasuhiro Oikawa; Kazuyo Yamauchi; Sumihisa Orita; Masashi Takaso; Tomoaki Toyone; Kazuhisa Takahashi; Seiji Ohtori
Journal:  Eur Spine J       Date:  2012-12-28       Impact factor: 3.134

3.  What Is the Value of Surgical Intervention for Sacral Metastases?

Authors:  Zhiye Du; Wei Guo; Rongli Yang; Xiaodong Tang; Tao Ji; Dasen Li
Journal:  PLoS One       Date:  2016-12-19       Impact factor: 3.240

4.  Anatomic Parameters for Instrumentation of the Sacrum and Pelvis: A Systematic Review of the Literature.

Authors:  Yoshihiro Katsuura; Eric Chang; Shahbaaz A Sabri; Warren E Gardner; Jesse F Doty
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2018-08-02

5.  Biomechanical Analysis of an S1 Pedicle Screw Salvage Technique via a Superior Articulating Process Entry Point.

Authors:  Yu-Po Lee; Hansel E Ihn; Michelle H McGarry; Saifal-Deen Farhan; Nitin Bhatia; Thay Q Lee
Journal:  Spine (Phila Pa 1976)       Date:  2016-07-01       Impact factor: 3.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.