Literature DB >> 8558739

Ultrasound-guided compression closure of postcatheterization pseudoaneurysms during concurrent anticoagulation: a review of seventy-seven patients.

S M Dean1, J W Olin, M Piedmonte, M Grubb, J R Young.   

Abstract

PURPOSE: Data from our institution and elsewhere have demonstrated that ultrasound-guided compression closure (UGCC) is an effective method of treating postcatheterization pseudoaneurysms. Whereas patients receiving anticoagulation do not have as high a success rate as those not receiving anticoagulants, there have been no large series evaluating the factors associated with success or failure in patients receiving anticoagulation. The purpose of this study is to determine whether uninterrupted anticoagulation interferes with successful UGCC of pseudoaneurysms and to identify factors associated with success or failure.
METHODS: From May 1991 to September 1994, 238 cases of attempted UGCC of pseudoaneurysms were performed in our vascular laboratory. Only patients who received uninterrupted heparin, warfarin, or both at the time of pseudoaneurysm compression were eligible for inclusion into the study. Seventy-seven patients were identified who met the study criteria.
RESULTS: Successful pseudoaneurysm compression was obtained in 56 (73%) patients, whereas 21 (27%) patients had a failed UGCC. In the successfully treated group, seven (12.5%) required between two to three compression attempts to induce sustained thrombosis. There was no statistical difference in age, sex, sheath size, days after procedure, location of pseudoaneurysm, or number of chambers in the pseudoaneurysm between those patients who had a successful repair and those who did not. If the pseudoaneurysm was less than 4 cm in diameter, 51 of 65 patients (78%) had a successful repair compared with 5 of 12 patients (42%) with a pseudoaneurysm of 4 cm or greater (p = 0.013). There was no statistical difference between success and failure in patients receiving warfarin alone (3.73 mean international normalized ratio, 72% success rate), heparin alone (mean activated partial thromboplastin time of 63 seconds, 92% success rate), or heparin and warfarin (mean activated partial thromboplastin time of 70 seconds, mean international normalized ratio of 4, success rate of 67%). No arterial or venous thrombosis occurred during pseudoaneurysm compression.
CONCLUSION: Successful UGCC of pseudoaneurysms occurred in a large percentage of patients receiving full-dose, uninterrupted anticoagulation. The only factor influencing success was the size of the pseudoaneurysm.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8558739     DOI: 10.1016/s0741-5214(05)80032-1

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  12 in total

1.  Pseudoaneurysms.

Authors:  Michael R. Jaff
Journal:  Curr Treat Options Cardiovasc Med       Date:  2002-06

2.  Ultrasound guided percutaneous thrombin injection of iatrogenic femoral artery pseudoaneurysms after coronary angiography and intervention.

Authors:  J D Ferguson; P J Whatling; V Martin; J Walton; A P Banning
Journal:  Heart       Date:  2001-04       Impact factor: 5.994

3.  Ultrasound-Guided Thrombin Injection Is a Safe and Effective Treatment for Femoral Artery Pseudoaneurysm in the Morbidly Obese.

Authors:  Taehwan Yoo; Jean E Starr; Michael R Go; Patrick S Vaccaro; Bhagwan Satiani; Mounir J Haurani
Journal:  Vasc Endovascular Surg       Date:  2017-05-31       Impact factor: 1.089

4.  Pseudoaneurysm: a review.

Authors:  Venkat R Kalapatapu; Kyla R Shelton; Ahsan T Ali; Mohammed M Moursi; John F Eidt
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-04

Review 5.  [Peripheral arterial complications after heart catheterization].

Authors:  M P Heintzen; B E Strauer
Journal:  Herz       Date:  1998-02       Impact factor: 1.740

Review 6.  Vascular complications of transcatheter aortic valve replacement: A concise literature review.

Authors:  Muhammad Ali Chaudhry; Muhammad Rizwan Sardar
Journal:  World J Cardiol       Date:  2017-07-26

7.  Ultrasound-guided thrombin injection versus ultrasound-guided compression repair in the treatment of post-catheterization femoral artery pseudoaneurysm: King Saud University Medical Center Experience.

Authors:  Talal Altuwaijri; Mussaad Alsalman; Abdulamjeed Altoijry; Kaisor Iqbal; Hesham AlGhofili
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2020-01-23       Impact factor: 0.332

8.  Ultrasound-guided thrombin injection versus ultrasound-guided compression therapy of iatrogenic femoral false aneurysms: Single center experience.

Authors:  Mohammed A Rashaideh; Kristi E Janho; Jameel S Shawaqfeh; Eyad Ajarmeh; Mohammed As'ad
Journal:  Med J Armed Forces India       Date:  2019-12-16

9.  Use of expanded polytetrafluoroethylen (ePTFE) stent graft in autogenic AV fistula with false aneurysm in lower extremity.

Authors:  Dominik Sieroń; Philipp Wiggermann; Daniel Knap; Wojciech Wawrzynek; Christian Stroszczynski
Journal:  Pol J Radiol       Date:  2012-04

10.  New technique for treatment of postcatheterization radial artery pseudoaneurysm.

Authors:  Avtandil M Babunashvili; Samir B Pancholy; Dmitriy S Kartashov
Journal:  Catheter Cardiovasc Interv       Date:  2016-08-16       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.