Literature DB >> 8553929

Prospective comparison of CT angiography of the legs with intraarterial digital subtraction angiography.

O Rieker1, C Düber, W Schmiedt, H von Zitzewitz, F Schweden, M Thelen.   

Abstract

OBJECTIVE: The aim of this study was to determine the accuracy of CT angiography (CTA) with a single spiral acquisition for the diagnosis of arterial stenoses and occlusion in patients with peripheral vascular occlusive disease. SUBJECTS AND METHODS: In a prospective study, intraarterial digital subtraction angiography and i.v. CTA from the groin to the lower calves were performed on 50 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were produced. The accuracy of CTA with and without analysis of the axial scans was determined with digital subtraction angiography as the standard.
RESULTS: The sensitivities of CTA were 100% for the diagnosis of femoral artery occlusion, 100% for the detection of popliteal artery (including tibial-peroneal arterial trunk) occlusion, and 94% for the detection of tibial artery occlusion. The specificities were 100%, 99%, and 98%, respectively. When maximum-intensity-projection images were interpreted without axial scans, sensitivities were 98%, 85%, and 92% and specificities were 100%, 99%, and 97%, respectively. For the accurate grading of high-grade (75-99%) stenoses of the superficial femoral artery and the popliteal artery (including tibial-peroneal arterial trunk), the sensitivities of CTA were 88% and 73% and the specificities were 94% and 100%, respectively. When maximum-intensity-projection images alone were used, the sensitivities for the correct grading of high-grade stenoses were 58% and 36% and the specificities were 99% and 100%, respectively.
CONCLUSION: CTA from the groin to the lower calves is feasible, and the short examination time is a significantly advantage over the time required for other noninvasive techniques. CTA is particularly accurate in the depiction of femoral artery occlusions. Maximum-intensity-projection images are useful, but analysis of axial scans is more accurate for the grading of arterial stenoses. The results of CTA are encouraging enough to warrant further studies. A CTA protocol covering the pelvic and pedal vessels remains to be established and evaluated.

Entities:  

Mesh:

Year:  1996        PMID: 8553929     DOI: 10.2214/ajr.166.2.8553929

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

Review 1.  Current concepts in the evaluation of vascular disease: magnetic resonance and computed tomographic angiography.

Authors:  B D Toombs; J M Jing
Journal:  Tex Heart Inst J       Date:  2000

2.  Popliteal artery entrapment syndrome: diagnosis and management, with report of three cases.

Authors:  V Radonić; S Koplić; L Giunio; I Bozić; J Masković; A Buća
Journal:  Tex Heart Inst J       Date:  2000

3.  Advances in vascular and cardiac MDCT imaging: peripheral arteries.

Authors:  M L Storto; D Battista
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 5.315

4.  Multidetector CT angiography in the assessment of peripheral arterial occlusive disease: accuracy in detecting the severity, number, and length of stenoses.

Authors:  R Schernthaner; A Stadler; F Lomoschitz; M Weber; D Fleischmann; J Lammer; Ch Loewe
Journal:  Eur Radiol       Date:  2007-12-19       Impact factor: 5.315

Review 5.  Endovascular intervention for peripheral artery disease.

Authors:  Arun K Thukkani; Scott Kinlay
Journal:  Circ Res       Date:  2015-04-24       Impact factor: 17.367

Review 6.  [Chronic critical ischemia of the lower leg: pretherapeutic imaging and methods for revascularization].

Authors:  M Treitl; V Ruppert; A K Mayer; C Degenhart; M Reiser; J Rieger
Journal:  Radiologe       Date:  2006-11       Impact factor: 0.635

7.  Multislice spiral CT angiography in peripheral arterial occlusive disease: a valuable tool in detecting significant arterial lumen narrowing?

Authors:  Horst R Portugaller; Helmut Schoellnast; Klaus A Hausegger; Kurt Tiesenhausen; Wilfried Amann; Andrea Berghold
Journal:  Eur Radiol       Date:  2004-04-28       Impact factor: 5.315

Review 8.  Korean Guidelines for Interventional Recanalization of Lower Extremity Arteries.

Authors:  Young Hwan Kim; Jae Ik Bae; Yong Sun Jeon; Chang Won Kim; Hwan Jun Jae; Kwang Bo Park; Young Kwon Cho; Man Deuk Kim
Journal:  Korean J Radiol       Date:  2015-07-01       Impact factor: 3.500

9.  Diagnostic Accuracy of Sixty Four Multi-Slice CT Angiography in Assessment of Arterial Cut-Off and Run-Off in Comparison with Surgical Findings.

Authors:  M Noaparast; A Rabani; F Karimian; M Bodaghabadi; S Aran; R Mirsharifi; A Jafarian; F Vaezi; H Ghanaati
Journal:  Iran J Radiol       Date:  2011-09-25       Impact factor: 0.212

10.  Multi-detector row computed tomography angiography of peripheral arterial disease.

Authors:  Marc C J M Kock; Marcel L Dijkshoorn; Peter M T Pattynama; M G Myriam Hunink
Journal:  Eur Radiol       Date:  2007-09-20       Impact factor: 5.315

  10 in total