Literature DB >> 8553410

Comparison of transcranial Doppler ultrasonography and transesophageal echocardiography to monitor emboli during coronary artery bypass surgery.

D Barbut1, F S Yao, D N Hager, P Kavanaugh, R R Trifiletti, J P Gold.   

Abstract

BACKGROUND AND
PURPOSE: Transcranial Doppler ultrasonography (TCD) is the standard technique for monitoring emboli in the cerebral circulation. Embolic signals have been detected with the use of this technique in most patients undergoing coronary artery bypass surgery. We previously reported that the majority of emboli are detected after release of aortic cross-clamps and partial occlusion clamps. In this study we compare the intraoperative use of TCD with transesophageal echocardiography (TEE) to monitor cerebral emboli.
METHODS: We simultaneously monitored 20 patients undergoing coronary bypass surgery with TCD and TEE. All patients also underwent routine TEE examination of the aorta.
RESULTS: Embolic signals were detected in all patients by both techniques. Mean total number of emboli was 535 +/- 109 by TEE compared with 133 +/- 28 by TCD. We found correlation between numbers of emboli detected by the two techniques at clamp placement and release (r = .65, P = .002). Clamp placement and release accounted for 84% of all emboli by TEE and 83% by TCD. By TEE, large, highly echogenic particles were detected after clamp release compared with small, barely echodense particles at the onset of bypass. No such distinction was apparent by TCD. We found correlation between severity of aortic atheroma and both TEE- (P = .003) and TCD-detected (P = .009) emboli.
CONCLUSIONS: TEE and TCD can both be used to continuously monitor emboli during coronary artery bypass surgery. However, TEE is invasive and justified only if it is being performed for intraoperative assessment of aortic atheromatosis or cardiac function.

Entities:  

Mesh:

Year:  1996        PMID: 8553410     DOI: 10.1161/01.str.27.1.87

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  4 in total

1.  Development of a new arterial-line filter design using computational fluid dynamics analysis.

Authors:  Daniel P Herbst; Hani K Najm
Journal:  J Extra Corpor Technol       Date:  2012-09

2.  Biofeedback: making the science real.

Authors:  Robert A Baker; Richard F Newland; Jayme Bennetts
Journal:  J Extra Corpor Technol       Date:  2009-12

Review 3.  Contemporary Neuroprotection Strategies during Cardiac Surgery: State of the Art Review.

Authors:  Palesa Motshabi-Chakane; Palesa Mogane; Jacob Moutlana; Gontse Leballo-Mothibi; Sithandiwe Dingezweni; Dineo Mpanya; Nqoba Tsabedze
Journal:  Int J Environ Res Public Health       Date:  2021-12-03       Impact factor: 3.390

4.  Cerebral oxygenation monitoring of patients during arthroscopic shoulder surgery in the sitting position.

Authors:  Sang-Hun Ko; Young Woo Cho; Se Hun Park; Jin-Gyu Jeong; Seung-Myeong Shin; Gun Kang
Journal:  Korean J Anesthesiol       Date:  2012-10-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.