Estimation of temperature during radiofrequency catheter ablation using impedance measurements.

W M Hartung1, M E Burton, A G Deam, P F Walter, K McTeague, J J Langberg.   

Abstract

Temperature monitoring during radiofrequency catheter ablation is useful but requires specialized equipment that is not generally available. Previous studies have shown that impedance characteristically decreases as the result of heating at the electrode-tissue interface. The purpose of the current study was to determine if impedance changes during radiofrequency current application could be used to estimate endocardial temperature in patients undergoing catheter ablation. Data from 43 patients treated with a thermistor ablation catheter were retrospectively analyzed. The slope of the initial 2 seconds of the impedance curve and subsequent changes in impedance were incorporated into an equation for estimation of temperature in real-time. The accuracy of this equation was assessed by prospectively comparing the calculated and measured temperatures in 19 patients. Of the 88% of energy applications that were suitable for analysis, the average difference between calculated and measured temperatures was 5.2 +/- 5.6 degrees C. The average error was < 10 degrees C in 89% of applications. The results of this study suggest that impedance measurements can be used to quantify tissue temperature in real-time during radiofrequency catheter ablation. This method is sufficiently accurate to allow titration of power output to produce temperatures in the useful range (50-80 degrees C) while avoiding excessive heating (> 90 degrees C).

Entities:  

Mesh:

Year:  1995        PMID: 8552515     DOI: 10.1111/j.1540-8159.1995.tb03862.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

1.  Precision test apparatus for evaluating the heating pattern of radiofrequency ablation devices.

Authors:  I Chang; B Beard
Journal:  Med Eng Phys       Date:  2002-11       Impact factor: 2.242

2.  Direct thermography-a new in vitro method to characterize temperature kinetics of ablation catheters.

Authors:  M Fiek; F Gindele; C von Bary; D Muessig; A Lucic; E Hoffmann; C Reithmann; G Steinbeck
Journal:  J Interv Card Electrophysiol       Date:  2013-07-14       Impact factor: 1.900

3.  Ablation Lesion Characterization in Scarred Substrate Assessed Using Cardiac Magnetic Resonance.

Authors:  Susumu Tao; Michael A Guttman; Sarah Fink; Hassan Elahi; Kaustubha D Patil; Hiroshi Ashikaga; Aravindan D Kolandaivelu; Ronald D Berger; Marc K Halushka; Ehud J Schmidt; Daniel A Herzka; Henry R Halperin
Journal:  JACC Clin Electrophysiol       Date:  2018-12-26

4.  In vitro and in vivo evaluation of the thermal patterns and lesions of catheter ablation with a microwave monopole antenna.

Authors:  David Keane; Jeremy Ruskin; Nancy Norris; Pierre-Antoine Chapelon; Dany Bérubé
Journal:  J Interv Card Electrophysiol       Date:  2004-04       Impact factor: 1.900

5.  Remote magnetic versus manual catheters: evaluation of ablation effect in atrial fibrillation by myocardial marker levels.

Authors:  Eivind Solheim; Morten Kristian Off; Per Ivar Hoff; Alessandro De Bortoli; Peter Schuster; Ole-Jørgen Ohm; Jian Chen
Journal:  J Interv Card Electrophysiol       Date:  2011-04-08       Impact factor: 1.900

6.  Mathematical models based on transfer functions to estimate tissue temperature during RF cardiac ablation in real time.

Authors:  Jose Alba-Martínez; Macarena Trujillo; Ramon Blasco-Gimenez; Enrique Berjano
Journal:  Open Biomed Eng J       Date:  2012-03-08

Review 7.  Impedance-guided Radiofrequency Ablation: Using Impedance to Improve Ablation Outcomes.

Authors:  Jason S Chinitz; Gregory F Michaud; Kent Stephenson
Journal:  J Innov Card Rhythm Manag       Date:  2017-10-15

8.  Characteristics of Very High-Power, Short-Duration Radiofrequency Applications.

Authors:  Gábor Orbán; Zoltán Salló; Péter Perge; Pál Ábrahám; Katalin Piros; Klaudia Vivien Nagy; István Osztheimer; Béla Merkely; László Gellér; Nándor Szegedi
Journal:  Front Cardiovasc Med       Date:  2022-07-13
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.