Literature DB >> 8545897

Evaluation of HLA antibodies with the PRA-STAT test. An ELISA test using soluble HLA class I molecules.

A A Zachary1, J Griffin, D P Lucas, J M Hart, M S Leffell.   

Abstract

HLA-specific antibody, present before or after transplantation, may adversely effect graft outcome. Antibody testing by cytotoxicity (CYT) is laborious, requires viable lymphocytes, does not differentiate non-HLA cytotoxic antibody, and cannot be used readily on specimens from patients being treated with cytotoxic antibodies. We have evaluated PRA-STAT, an antibody screening kit that uses an ELISA test with soluble HLA class I molecules as targets. We performed 219 tests on a variety of serum specimens, 128 of which were also tested by CYT. There was a highly significant correlation (r = 0.78, P < 0.001) between PRA-STAT (PS) and CYT for the detection of IgG antibodies. Of 66 sera reactive in both assays, 18% had identical specificities defined in both, 27% were more reactive in PS than in CYT, 8% were more reactive in CYT, and 47% had different specificities in the 2 assays, with overlap in slightly more than half the cases. Of 13 sera reactive only in PS, 2 were from non-transfused, nontransplanted males with no evidence of lymphocyte-reactive antibody by antiglobulin tests. PS uses an IgG-specific conjugate, therefore IgM class I-specific antibodies cannot be identified--however, their presence does affect test outcome. This, as well as the panel composition and interlot reproducibility, are areas we believe need to be addressed. The PRA-STAT system is rapid, does not require viable cells or complement, and can be automated in part. Resolution of the problems identified here and availability of an IgM-specific conjugate should make this test system a valuable tool in histocompatibility testing.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8545897     DOI: 10.1097/00007890-199560120-00038

Source DB:  PubMed          Journal:  Transplantation        ISSN: 0041-1337            Impact factor:   4.939


  3 in total

Review 1.  Sensitive solid-phase detection of donor-specific antibodies as an aid highly relevant to improving allograft outcomes.

Authors:  Gerald Schlaf; Beatrix Pollok-Kopp; Wolfgang W Altermann
Journal:  Mol Diagn Ther       Date:  2014-04       Impact factor: 4.074

2.  HLA-antibody testing: the immune phagocytosis inhibition test is superior to the PRA-STAT and NIH lymphocytotoxic test with respect to specificity.

Authors:  B K Flesch; M Philipp; U Cassens; J Neppert
Journal:  J Clin Lab Anal       Date:  2001       Impact factor: 2.352

3.  Novel solid phase-based ELISA assays contribute to an improved detection of anti-HLA antibodies and to an increased reliability of pre- and post-transplant crossmatching.

Authors:  Gerald Schlaf; Beatrix Pollok-Kopp; Till Manzke; Oliver Schurat; Wolfgang Altermann
Journal:  NDT Plus       Date:  2010-09-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.