Literature DB >> 8545600

Interference of gadodiamide injection (OMNISCAN) on the colorimetric determination of serum calcium.

P T Normann1, A Frøysa, M Svaland.   

Abstract

The interference of the non-ionic magnetic resonance contrast medium gadodiamide injection (OMNISCAN, Nycomed Imaging, Oslo, Norway) in the colorimetric determination of serum calcium has been investigated in commercial reconstituted serum, and in serum from rabbits and humans dosed with the contrast medium. Inductively coupled plasma-atomic emission spectroscopy (ICP-AES) and ion-selective electrodes were used as reference methods for analysis of serum calcium. The results showed that the colorimetric reagent kit gave an apparent decrease in serum calcium after administration of a clinical dose of gadodiamide injection, and that the extent of interference is correlated to the concentration of the contrast medium. However, serum calcium was not changed when measured by means of an ion-selective electrode or ICP-AES. It is therefore recommended that colorimetric reagent kits should not be used for determination of serum calcium in samples taken within the first 24 h after administration of gadodiamide injection.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8545600     DOI: 10.3109/00365519509104981

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  8 in total

Review 1.  Contrast media: interactions with other drugs and clinical tests.

Authors:  Sameh K Morcos; Henrik S Thomsen; C M Exley
Journal:  Eur Radiol       Date:  2005-01-26       Impact factor: 5.315

2.  Spurious hypocalcemia after gadodiamide-enhanced magnetic resonance imaging: a case report and review of the literature.

Authors:  Christopher D Moore; Robert C Newman; James G Caridi
Journal:  Rev Urol       Date:  2006

3.  New method for calcium on the ADVIA analyzer is free from interference of gadolinium-type contrast agents.

Authors:  Pradip Datta; Amitava Dasgupta
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

Review 4.  [Contrast agents in MRT. Substance, effects, pharmacology and validity].

Authors:  P Reimer; R Vosshenrich
Journal:  Radiologe       Date:  2004-03       Impact factor: 0.635

5.  Analytical Interference by Contrast Agents in Biochemical Assays.

Authors:  Sigrid Otnes; Niels Fogh-Andersen; Janne Rømsing; Henrik S Thomsen
Journal:  Contrast Media Mol Imaging       Date:  2017-04-10       Impact factor: 3.161

6.  Evaluation of the novel USPIO GEH121333 for MR imaging of cancer immune responses.

Authors:  Qiaoyun Shi; Laura J Pisani; Yauk K Lee; Solomon Messing; Celina Ansari; Srabani Bhaumik; Lisa Lowery; Brian D Lee; Dan E Meyer; Heike E Daldrup-Link
Journal:  Contrast Media Mol Imaging       Date:  2013 May-Jun       Impact factor: 3.161

Review 7.  Interference of medical contrast media on laboratory testing.

Authors:  Giuseppe Lippi; Massimo Daves; Camilla Mattiuzzi
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

8.  Analytical interference in serum iron determination reveals iron versus gadolinium transmetallation with linear gadolinium-based contrast agents.

Authors:  Nathalie Fretellier; Nathalie Poteau; Cécile Factor; Jean-François Mayer; Christelle Medina; Marc Port; Jean-Marc Idée; Claire Corot
Journal:  Invest Radiol       Date:  2014-12       Impact factor: 6.016

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.