Force delivery of Ni-Ti coil springs.

C Manhartsberger1, W Seidenbusch.   

Abstract

Sentalloy springs (GAC, Central Islip, N.Y.) of the open and closed type were investigated with a special designed device. The closed coil springs were subjected to a tensile and the open coil springs to a compression test. After a first measurement, the springs were activated for a period of 4 weeks and then reinvestigated with the same procedure. It could be shown distinctly that, with the different coil springs, the force delivery given by the producer could be achieved only within certain limits. To remain in the martensitic plateau, changed activation ranges, and for the Sentalloy coil springs white and red of the open and closed type, also changed force deliveries had to be taken into account. There was a distinct decrease in force delivery between the first and second measurement. After considering the loading curves of all the Sentalloy coil springs and choosing the right activation range respective to the force delivery, it was found that the coil springs deliver a superior clinical behavior and open new treatment possibilities.

Mesh:

Substances:

Year:  1996        PMID: 8540487     DOI: 10.1016/s0889-5406(96)70158-0

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Mass retraction movement of the anterior upper teeth using orthodontic mini-implants as anchorage.

Authors:  Leonardo Henrique de Lima Araújo; Elton Gonçalves Zenóbio; Wellington Pacheco; Maurício Greco Cosso; Flávio Ricardo Manzi; Jamil Awad Shibli
Journal:  Oral Maxillofac Surg       Date:  2011-01-28

2.  Deformation of nickel-titanium closed coil springs: an in vitro study.

Authors:  Camilla Ivini Viana Vieira; José Maurício Dos Santos Nunes Reis; Luiz Geraldo Vaz; Lídia Parsekian Martins; Renato Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2017-02

3.  Mechanical evaluation for three-dimensional printed orthodontic springs with different heights-in vitro study.

Authors:  Dragan Ströbele; Ahmed Othman; Vasilios Alevizakos; Mesut Turan; Constantin von See
Journal:  J Clin Exp Dent       Date:  2021-10-01

4.  In-vivo force decay of nickel-titanium closed-coil springs.

Authors:  Crystal Cox; Tung Nguyen; Lorne Koroluk; Ching-Chang Ko
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-04       Impact factor: 2.650

5.  Forces of various nickel titanium closed coil springs.

Authors:  Anthony Louis Maganzini; Alan M Wong; Mairaj K Ahmed
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

6.  Effects of reversing the coiling direction on the force-deflection characteristics of nickel-titanium closed-coil springs.

Authors:  Hwan-Hyung Park; Suk-Hwan Jung; Juil Yoon; Kwang Koo Jee; Jun Hyun Han; Seung-Hak Baek
Journal:  Korean J Orthod       Date:  2019-07-22       Impact factor: 1.372

7.  The Effect of Orthodontic Forces on Tooth Response to Electric Pulp Test.

Authors:  Jalil Modaresi; Hosein Aghili; Omid Dianat; Farnaz Younessian; Faranak Mahjour
Journal:  Iran Endod J       Date:  2015
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.