Literature DB >> 8533046

The accuracy of MRI-determined synovial membrane and joint effusion volumes in arthritis. A comparison of pre- and post-aspiration volumes.

M Ostergaard1, M Stoltenberg, O Henriksen, I Lorenzen.   

Abstract

Magnetic resonance imaging (MRI) of 18 knees of patients with arthritis was performed before and immediately after arthrocentesis. Pre- and post-aspiration volumes were calculated by adding the outlined areas of synovium/effusion from a continuous series of gadolinium-DTPA-enhanced 5 mm transversal T1-weighted MR-images. The difference between MRI-determined and syringe-determined volumes of aspirated joint fluid was 0-7 ml, median 2 ml, corresponding to 0-18%, median 7%, of the pre-aspiration effusion volume. Synovial membrane volumes, determined before and after arthrocentesis varied 0-10 ml, median 3 ml (0-17%, median 7%). No significant systematic misinterpretation of the borderline between joint fluid and synovium was found. We conclude that effusion volumes and in all probability also synovial membrane volumes, can be determined by MRI with a maximal analytical error of approximately 20%. The acceptable accuracy of the method encourages further studies of the value of effusion and synovial membrane volumes as markers of the activity and/or severity of joint inflammation.

Entities:  

Mesh:

Year:  1995        PMID: 8533046     DOI: 10.3109/03009749509095168

Source DB:  PubMed          Journal:  Scand J Rheumatol        ISSN: 0300-9742            Impact factor:   3.641


  7 in total

1.  Does running cause metatarsophalangeal joint effusions? A comparison of synovial fluid volumes on MRI in athletes before and after running.

Authors:  Amy-Rose Kingston; Andoni P Toms; Subhadip Ghosh-Ray; Shelley Johnston-Downing
Journal:  Skeletal Radiol       Date:  2009-01-30       Impact factor: 2.199

2.  Low field dedicated magnetic resonance imaging in untreated rheumatoid arthritis of recent onset.

Authors:  H Lindegaard; J Vallø; K Hørslev-Petersen; P Junker; M Østergaard
Journal:  Ann Rheum Dis       Date:  2001-08       Impact factor: 19.103

3.  Comparing intra-articular CTXII levels assessed via magnetic capture or lavage in a rat knee osteoarthritis model.

Authors:  E G Yarmola; Y Y Shah; H E Kloefkorn; J Dobson; K D Allen
Journal:  Osteoarthritis Cartilage       Date:  2017-01-28       Impact factor: 6.576

4.  Quantitative magnetic resonance imaging as marker of synovial membrane regeneration and recurrence of synovitis after arthroscopic knee joint synovectomy: a one year follow up study.

Authors:  M Ostergaard; B Ejbjerg; M Stoltenberg; P Gideon; B Volck; K Skov; C H Jensen; I Lorenzen
Journal:  Ann Rheum Dis       Date:  2001-03       Impact factor: 19.103

5.  MRI assessment of knee osteoarthritis: Knee Osteoarthritis Scoring System (KOSS)--inter-observer and intra-observer reproducibility of a compartment-based scoring system.

Authors:  Peter R Kornaat; Ruth Y T Ceulemans; Herman M Kroon; Naghmeh Riyazi; Margreet Kloppenburg; Wayne O Carter; Thasia G Woodworth; Johan L Bloem
Journal:  Skeletal Radiol       Date:  2004-10-08       Impact factor: 2.199

6.  Importance of timing of post-contrast MRI in rheumatoid arthritis: what happens during the first 60 minutes after IV gadolinium-DTPA?

Authors:  M Østergaard; M Klarlund
Journal:  Ann Rheum Dis       Date:  2001-11       Impact factor: 19.103

7.  Fully automated system for the quantification of human osteoarthritic knee joint effusion volume using magnetic resonance imaging.

Authors:  Wei Li; François Abram; Jean-Pierre Pelletier; Jean-Pierre Raynauld; Marc Dorais; Marc-André d'Anjou; Johanne Martel-Pelletier
Journal:  Arthritis Res Ther       Date:  2010-09-16       Impact factor: 5.156

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.