A model for electron-beam applicator scatter.

M A Ebert1, P W Hoban.   

Abstract

Applicators (or cones), used in conjunction with patient specific cutouts in electron-beam radiotherapy, may interact with the primary electron beam to produce a secondary beam component (applicator scatter). This component affects machine output as well as the shape of resulting dose distributions. A model has been developed to simulate this scatter component for applicators consisting of trimming plates of arbitrary shape. This model involves sampling established kernels of scatter from edge elements of appropriate materials, obtained through Monte Carlo simulations. The result of the model is a phase space (position, direction, energy, charge, weighting) of applicator scattered particles which can be incorporated into a further Monte Carlo simulation, or as input into another advanced treatment planning algorithm. This model is evaluated by comparison of measured profiles and applicator scatter component depth dose curves with Monte Carlo simulations using simulated phase-space data as input. Results are very consistent and reveal information on the angular and spatial variation characteristics of this beam component. The results obtained verify the developed model as an accurate predictor of the characteristics of applicator scattered particles.

Entities:  

Mesh:

Year:  1995        PMID: 8531867     DOI: 10.1118/1.597415

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

Review 1.  Some computer graphical user interfaces in radiation therapy.

Authors:  James C L Chow
Journal:  World J Radiol       Date:  2016-03-28

2.  Potential therapeutic misadministration due to inappropriate electron beam field shaping.

Authors:  A J Olch; R Fallen; J Conrad; R S Lavey
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

3.  Clinical implementation of an electron monitor unit dosimetry system based on task group 71 report and a commercial calculation program.

Authors:  Huijun Xu; Mariana Guerrero; Shifeng Chen; Xiaocheng Yang; Karl Prado; Colleen Schinkel
Journal:  J Med Phys       Date:  2016 Oct-Dec

4.  A graphical user interface for an electron monitor unit calculator using a sector-integration algorithm and exponential curve-fitting method.

Authors:  James C L Chow; Grigor N Grigorov; Christopher MacGregor
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

5.  Radiation leakage dose from Elekta electron collimation system.

Authors:  Garrett M Pitcher; Kenneth R Hogstrom; Robert L Carver
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  5 in total