Literature DB >> 8526620

Disparity in blood activation by two different heparin-coated cardiopulmonary bypass systems.

O Moen1, E Fosse, V Brockmeier, C Andersson, T E Mollnes, K Høgåsen, P Venge.   

Abstract

BACKGROUND: Several studies have indicated reduced "blood activation" in heparin-coated cardiopulmonary bypass systems. The present study compares the effect of two different heparin coatings on different blood activation indices.
METHODS: Low-risk patients (n = 40) were randomized to coronary artery bypass grafting using cardiopulmonary bypass with surfaces coated entirely by either the Duraflo II heparin coat or the Carmeda Biological Active Surface, or with identical uncoated equipment. In all cases, a standard systemic heparin dosage was used. Complement activation (C3 activation products C3bc and C3a and formation of fluid phase terminal SC5b-9 complement complex), neutrophil activation (lactoferrin and myeloperoxidase), and lytic inhibitors (vitronectin and clusterin) were quantified during cardiopulmonary bypass and 6 hours postoperatively.
RESULTS: Heparin coating by either method reduced the formation of terminal SC5b-9 complement complex and the release of lactoferrin and myeloperoxidase compared with uncoated systems. Lactoferrin and myeloperoxidase levels increased significantly during cardiopulmonary bypass in the Duraflo II group, whereas no significant increase was observed in the Carmeda Biological Active Surface group. The least formation of terminal SC5b-9 complement complex and neutrophil activation was observed with the Maxima Carmeda Biological Active Surface-coated equipment. The vitronectin and clusterin concentrations were significantly less reduced in the Duraflo II compared with the control group. This study underlines the importance of terminal SC5b-9 complement complex as a suitable marker in the evaluation of complement activation during cardiopulmonary bypass.
CONCLUSIONS: Both heparin coatings reduce blood activation, probably more so with Carmeda Biological Active Surface than with Duraflo II.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8526620     DOI: 10.1016/0003-4975(95)00777-i

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

Review 1.  How novel structures inform understanding of complement function.

Authors:  Elena Goicoechea de Jorge; Hugo Yebenes; Marina Serna; Agustín Tortajada; Oscar Llorca; Santiago Rodríguez de Córdoba
Journal:  Semin Immunopathol       Date:  2017-08-14       Impact factor: 9.623

Review 2.  Development and hemocompatibility testing of nitric oxide releasing polymers using a rabbit model of thrombogenicity.

Authors:  Terry C Major; Hitesh Handa; Gail M Annich; Robert H Bartlett
Journal:  J Biomater Appl       Date:  2014-06-16       Impact factor: 2.646

3.  Rewarming From Hypothermic Cardiac Arrest Applying Extracorporeal Life Support: A Systematic Review and Meta-Analysis.

Authors:  Lars J Bjertnæs; Kristian Hindberg; Torvind O Næsheim; Evgeny V Suborov; Eirik Reierth; Mikhail Y Kirov; Konstantin M Lebedinskii; Torkjel Tveita
Journal:  Front Med (Lausanne)       Date:  2021-05-13

Review 4.  Physiological Changes in Subjects Exposed to Accidental Hypothermia: An Update.

Authors:  Lars J Bjertnæs; Torvind O Næsheim; Eirik Reierth; Evgeny V Suborov; Mikhail Y Kirov; Konstantin M Lebedinskii; Torkjel Tveita
Journal:  Front Med (Lausanne)       Date:  2022-02-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.