Literature DB >> 8525099

A simple method for measuring glomerular filtration rate in dogs.

A Gleadhill1, A M Peters, A R Michell.   

Abstract

A technique for measuring glomerular filtration rate (by six-sample plasma clearance) and extracellular fluid volume is described. The results obtained for glomerular filtration rat per extracellular fluid volume with a three blood sample technique are also presented. Concurrently with the blood sample techniques measuring plasma clearance, glomerular filtration rate per extracellular fluid volume was also measured using an external radiation detector and no blood samples. The validity of expressing glomerular filtration rate per extracellular fluid volume (rather than per body weight or surface area) and the clinical utility of the results obtained with the external radiation detector are discussed.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8525099     DOI: 10.1016/0034-5288(95)90044-6

Source DB:  PubMed          Journal:  Res Vet Sci        ISSN: 0034-5288            Impact factor:   2.534


  5 in total

1.  Glomerular filtration rate in relation to extracellular fluid volume: similarity between 99mTc-DTPA and inulin.

Authors:  R D Gunasekera; D J Allison; A M Peters
Journal:  Eur J Nucl Med       Date:  1996-01

2.  Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs.

Authors:  Jinhwa Chang; Sujin Kim; Joohyun Jung; Heechun Lee; Hojung Choi; Dongwoo Chang; Youngwon Lee; Junghee Yoon; Mincheol Choi
Journal:  J Vet Sci       Date:  2011-12       Impact factor: 1.672

3.  A pilot study to assess the feasibility of transcutaneous glomerular filtration rate measurement using fluorescence-labelled sinistrin in dogs and cats.

Authors:  Sarah Steinbach; Nora Krolop; Sellyn Strommer; Zeneida Herrera-Pérez; Stefania Geraci; Jochen Friedemann; Norbert Gretz; Reto Neiger
Journal:  PLoS One       Date:  2014-11-25       Impact factor: 3.240

4.  Determination of extracellular fluid volume in healthy and azotemic cats.

Authors:  N C Finch; R Heiene; J Elliott; H M Syme; A M Peters
Journal:  J Vet Intern Med       Date:  2014-11-19       Impact factor: 3.333

5.  Measurement of single kidney glomerular filtration rate in dogs using dynamic contrast-enhanced magnetic resonance imaging and the Rutland-Patlak plot technique.

Authors:  Jan-Niklas Mehl; Matthias Lüpke; Ann-Cathrin Brenner; Peter Dziallas; Patrick Wefstaedt; Hermann Seifert
Journal:  Acta Vet Scand       Date:  2018-11-06       Impact factor: 1.695

  5 in total