Literature DB >> 852465

Comparative Doppler directional sonographic and ophthalmodynamographic study in the occlusion of the internal carotid artery.

G Nappi, G Bono, M Poloni, F Savoldi.   

Abstract

In the occlusion of the internal carotid artery, the change occurring in the internal-external carotid pressure gradient may cause flow reversal within the ophthalmic artery and its branches. Ophthalmodynamographic, Doppler directional sonographic and angiographic investigations were performed in 21 cases (11 total occlusions, 6 severe and 4 moderate stenoses of the internal carotid artery). The authors compare the results of these investigations and discuss the practical importance of Doppler directional sonography and the significance of flow reversal in the ophthalmic artery.

Mesh:

Year:  1977        PMID: 852465     DOI: 10.1159/000114796

Source DB:  PubMed          Journal:  Eur Neurol        ISSN: 0014-3022            Impact factor:   1.710


  2 in total

1.  Functional anatomy of extracranial arteries in occlusive vascular diseases by direct continuous wave Doppler sonography.

Authors:  H C Diener; J Dichgans; K Voigt
Journal:  Cardiovasc Intervent Radiol       Date:  1981       Impact factor: 2.740

2.  Ophthalmodynamography and ophthalmodynamometry in neurological practice.

Authors:  F Strik
Journal:  Doc Ophthalmol       Date:  1980-05-30       Impact factor: 2.379

  2 in total