Literature DB >> 8524030

A computer simulation program for MR imaging: application to RF and static magnetic field imperfections.

M B Olsson1, R Wirestam, B R Persson.   

Abstract

A computer simulation program capable of demonstrating various artifacts, such as image distortion caused by metallic implants in MR imaging, is presented. The structure of the program allows for the implementation of various imaging situations as long as spins only experience weak interaction, i.e., the Bloch equations are obeyed. The raw data are obtained by repeatedly applying the Bloch equations to the magnetization vector of each point of the simulated object, throughout the pulse sequence. With only a limited number of spins in each voxel, the effects of intravoxel dephasing and rephasing require special attention, and algorithms for this have been implemented.

Mesh:

Substances:

Year:  1995        PMID: 8524030     DOI: 10.1002/mrm.1910340418

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Computer-generated fMRI phantoms with motion-distortion interaction.

Authors:  Ning Xu; J Michael Fitzpatrick; Yong Li; Benoit M Dawant; David R Pickens; Victoria L Morgan
Journal:  Magn Reson Imaging       Date:  2007-06-21       Impact factor: 2.546

Review 2.  A Review of Numerical Simulation and Analytical Modeling for Medical Devices Safety in MRI.

Authors:  J Kabil; L Belguerras; S Trattnig; C Pasquier; J Felblinger; A Missoffe
Journal:  Yearb Med Inform       Date:  2016-11-10

3.  Simulation of High-Resolution Magnetic Resonance Images on the IBM Blue Gene/L Supercomputer Using SIMRI.

Authors:  K G Baum; G Menezes; M Helguera
Journal:  Int J Biomed Imaging       Date:  2011-04-10

4.  Fast Realistic MRI Simulations Based on Generalized Multi-Pool Exchange Tissue Model.

Authors:  Fang Liu; Julia V Velikina; Walter F Block; Richard Kijowski; Alexey A Samsonov
Journal:  IEEE Trans Med Imaging       Date:  2016-10-25       Impact factor: 10.048

5.  Numerical simulation of time-resolved 3D phase-contrast magnetic resonance imaging.

Authors:  Thomas Puiseux; Anou Sewonu; Ramiro Moreno; Simon Mendez; Franck Nicoud
Journal:  PLoS One       Date:  2021-03-26       Impact factor: 3.240

6.  Development and validation of a new MRI simulation technique that can reliably estimate optimal in vivo scanning parameters in a glioblastoma murine model.

Authors:  Andrea Protti; Kristen L Jones; Dennis M Bonal; Lei Qin; Letterio S Politi; Sasha Kravets; Quang-Dé Nguyen; Annick D Van den Abbeele
Journal:  PLoS One       Date:  2018-07-23       Impact factor: 3.240

  6 in total